Page 23 of 31
VARIABLE TIME SCHEDULE NUMBER
CORRECTION OF BEGIN AND END TIME (SLAVE MODE)
Correct the actual “Begin” and “End” times (last column): enter a correction under the “Begin” and “End” times
(first column) (maximum correction
+ or - 8:00 h
). This may be necessary, for example if the master timer is
used for several time processes with the same number of periods.
LIGHT TIMER (CONTROLLED LIGHT)
SETTINGS
Time schedule: see “Master timer”.
Option to use a light regulation so that the lights are switched on/off gradually
(to create ideal day and night-time conditions - daybreak switching program).
A light regulation period consists of:
•
Starting time when the light intensity should be intensified or dimmed.
•
: the time (period) during which the light intensity should be intensified
or dimmed.
•
The desired light intensity at the end of the intensification or dimming
period.
Slave
If the light timer is linked to the master timer: the times are related to the times
of the master timer (after this there is still a possibility to correct the starting
and end times (+/– 8 hours).
Touch
: extra settings appear with a light regulation for:
1.
Minimum light intensity.
2.
Maximum light intensity.
3.
Light on dimming time (intensification period).
4.
Light off dimming time (dimming period).
5.
Lighting delay (twilight time).
3
4 5
1
2
INSPECTION LIGHT
Option to can manually switch the light on (using a pushbutton) in order to inspect the houses. The light is then
switched on for a certain time (can be set by the installer). If the pushbutton is pressed again during the “On
period”, the light will immediately be switched off again.