INSTallaTION
Installation
www.stiebel-eltron.com
WPE-I H(K) 230 Premium |
9
9.2 Siting
f
f
Remove the packaging film and the top and side EPS pad-
ding.
f
f
Tilt the appliance forwards slightly.
f
f
Place wooden blocks underneath the back of the appliance.
f
f
Tilt the appliance backwards slightly and remove it from the
EPS pallet. To do this, use the handles provided at the back
and the front adjustable rubber feet at the bottom.
f
f
Position the appliance on the prepared substrate.
f
f
Observe minimum distances (see chapter "Preparations /
Minimum clearances").
f
f
Level the appliance horizontally by adjusting the feet.
9.3 Removing the casing parts
Note
When you open the appliance, check the sealing tape.
The sealing tape is required for generating the necessary
negative pressure.
f
f
Replace the sealing tape if required.
1.
2.
D
00000
82
700
f
f
Remove the screws on both sides of the appliance.
f
f
Slide the handles on both sides of the appliance along the
guide as far as they will go.
Removing the cover
1.
2.
D
00000
82
69
9
f
f
Pull the cover forwards.
f
f
Hang the cover down in front of the appliance.
Removing the front panel
D
00000
82
69
8
f
f
Remove the front panel by pulling it towards the front.
Removing the side casing
D
00000
88
16
3
f
f
Remove the front panel (see "Removing the front panel").
f
f
Remove the screws.
f
f
Pivot the side casing to the side.
f
f
If necessary, lift the side casing out of the rear hinges. Pay
attention to any electrical cables.
Summary of Contents for WPE-I 04 H 230 Premium
Page 21: ...Installation Maintenance www stiebel eltron com WPE I H K 230 Premium 21 ...
Page 27: ...Installation Specification www stiebel eltron com WPE I H K 230 Premium 27 ...
Page 31: ...Installation Specification www stiebel eltron com WPE I H K 230 Premium 31 ...
Page 47: ...www stiebel eltron com WPE I H K 230 Premium 47 NOTES ...