Specification
15. Specification
15.1 Dimensions and connections
SHC 10 | SHC 15 Stiebel
a10
c01
c06
c01
i13
100
a20
80
a30
D
00000
39
384
SHC 10
SHC 10 GB
Eltron
a10 Appliance
Height
mm
430
430
a20 Appliance
Width
mm
280
280
a30 Appliance
Depth
mm
270
270
c01 Cold water inlet
Male thread
G 1/2 A
G 1/2 A
Top clearance
mm
26,5
26,5
c06 DHW outlet
Male thread
G 1/2 A
G 1/2 A
i13 Wall mounting bracket Height
mm
320
320
Hole spacing
horizontal
mm
140
140
SHC 15 SHC 15 GB
Eltron
a10 Appliance
Height
mm
452
452
a20 Appliance
Width
mm
320
320
a30 Appliance
Depth
mm
318
318
c01 Cold water inlet
Male thread
G 1/2 A
G 1/2 A
Top clearance
mm
23
23
c06 DHW outlet
Male thread
G 1/2 A
G 1/2 A
i13 Wall mounting bracket Height
mm
342
342
Hole spacing
horizontal
mm
200
200
15.2 Wiring diagram
1/N/PE ~ 220-240 V
L
A
B
N
PE
1
2
D
00000
35
81
0
15.3 Heat-up diagram
The heat-up period depends on the degree of scaling and residual
heat. For the heat-up time for a cold water supply at 10 °C and a
maximum temperature setting, see the diagram.
35
40
45
50
55
60
65
0
5
10
15
20
25
30
35
40
1
2
D
00000
39
37
7
x Temperature in °C
y Duration in min
1 15 l appliance
2 10 l appliance
15.4 Country-specific approvals and certifications
The test symbols can be seen on the type plate.
15.5 Extreme operating and fault conditions
In the case of faults, a peak temperature of up to 99 °C may briefly
occur in the system.