INSTALLATIoN
Installation
18 |
WST-W | TWS 2 | AHu 50
5.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
6. Installation
!
Material losses
The water heater may develop a leak.
f
f
Never subject the water heater to water pressure.
≤45
D
00000
72
34
8
2
3
4
5
6
7
1
8
Illustration: WST-W
1 Pivoting spout
2 Tap body
3 Gasket
4 Connection hoses
5 Clamping ring
6 Support ring
7 Mating fitting (spanner size 11)
8 Eyelet for plug chain
f
f
Route the connection pipes through the aperture. To do this,
the gasket must be positioned under the tap body.
f
f
Secure the tap using the clamping ring, the support ring and
the mating fitting.
f
f
Fit the pivoting spout to the tap body.
6.1 Water connection
!
Material losses
Observe the maximum permissible flow rate with a fully
opened shut-off valve (see chapter "Specification / Data
table") when using non-pressurised water heaters.