background image

13.56 MHz  
Desktop Reader  
Installation instructions 

 

13,56 MHz 
Lecteur de table  
Notice d’installation

 

13.56 MHz

 

 

Lector de mesa 
Procedimiento de instalación

  

conforme con

 NOM-024 -SCFI-2013

 

 

 

© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1114B03- Page 

1

 sur 

-

 

Ed. 27/06/2019 

STid reserves the right to make change without notice, for the purpose of product improvement.

 

 

 

Product references 

 

 

Characteristics  

Communication:  

USB 

Cable output:  

USB 2.0 cable 

– Length 1.50m – Connector type A - chip FTDI 

 

Driver installation 

If the reader is shipped outside of the STid Software Kit: 

 

-  Please, click on this url: 

http://www.ftdichip.com/FTDrivers.htm

 

-  Download the VCP driver according your operating system. 
-  Connect the reader to the computer with the USB wire furnished. 
-  Waiting few seconds that the PC recognizes the USB port. 
-  Launch the installation. 

 

Buzzer / LED 

The operating mode for the Buzzer and LED 1 and 2 can be programmed by a configuration card (R3x & S3x) or controlled by the communication protocol of the 
reader (W3x). 

 

Read-only reader configuration  

R and S readers are configurable with the SCB configuration card or virtual configuration card created with SECard. 

 

If the SCB is compatible with the 

reader’s firmware, the LED lights green and the buzzer beeps five times. 

 

If the SCB is not compatible with the 

reader’s firmware, the LED lights red and the buzzer is activated for 1 s. 

Caution: set your reader with your own company key. 

 

Powering-up the readers  

On power-up, the reader enters an initialization phase: 

1.  Activation of the white LED and buzzer for 100 ms. 

 

For read-only readers: 

2.  Activation of the LED, according to the color code: Red = +10, Orange = +5, Green = +1, indicating the firmware version.

 

 

3.  For serial R/S reader only: the orange LED flashes 20 times: waiting for an update. 
4.  For ARCS Blue only: Activating white fixed LED during Bluetooth initialization. 
5.  Activation of the default LED (flashes blue if no customer specific configuration). 

 

Default parameters configuration  

 

Reader power off, the default reader settings can be stored in internal memory accessible by UHF RFID technology. They will be taken into account 
when reader is power on. 

 

Caution for Bluetooth reader  

Caution: at the reader Bluetooth (BT1) powering, make sure that nothing is in an area of at least 10 cm / 3.94 in around the  reader (ex. No 
hand in front of the reader…). 

 

Communication  

More details about reader communication are available in SECard User Manual for read only readers or in the protocol specification SSCP for read/write readers. 

 

Precautions for installation 

  As far as possible, keep the reader away from computer or power source cables. They can generate electrical interference, depending on their radiation level 

and the proximity of the reader. 

  Recommended distance between two readers: parallel plane: 15.8 in; same plane: 15.8 in; perpendicular plane: 11.8 in// two Blue readers: 6.56 ft either plan.

 

 

  Readers installed on a metal surface may have reduced performances. 

  Operating temperature: -4 °F to 158 °F / -20°C to +70°C. 

 

Dimensions 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 

General tolerance following ISO NFT 58-000 standard.

 

 

Declaration of compliance 

 

STid  declares  that  the  ARCS  reader  is  compliant  with  the  essential  requirements  of  the  Directives  RED  2014/53/UE  and  RoHs  2011/65/UE.  A  copy  of  our 
declaration is available on request from 

[email protected]

 
 

This device complies with Part 15 of the FCC rules and with ISED’s license–exempt RSSs. Operation is subject to the following two conditions: 

1) This device may not cause harmful interference. 
2) This device must accept any interference received, including interference that may cause undesired operation. 

 

Note: the manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications 
could void the user’s authority to operate the equipment. 
This device complies with the safety requirements for RF exposure in accordance with RSS-102 issue 5 for conditions of use.  

 

 

“DEEE Pro” Member 

 
In accordance with the provisions of the Environment Code, STid finances the collection, decontamination and recycling of WEEE provided by 
ESR-RECYLUM, to which STid adheres and to which it has transferred its regulatory responsibilities as a Producer. 
STid recommends that owners of used equipment who wish to dispose of it return it as WEEE by contacting ESR / RECYLUM in order to benefit 
from the solutions at no additional cost of collecting and recycling used equipment. More information on 

www.recylum.fr

 

ARCS-x35-G/PH5 

ARCS-x35-G/BT1 

US 

FR 

ES 

3.15 in 

1.09 in 

4

.2

2

 i

n

 

Reviews: