Stid ARC1-XY Installation Instructions Manual Download Page 1

ARC1 Mini Mullion reader  
MA1 OEM Module 
Installation instructions 

 

Lecteur Etroit ARC1    
Module OEM MA1  
Notice 

d’installation

 

Lector Estrecho ARC1  
Módulo OEM MA1 
Procedimiento de instalación  
conforme con

 NOM-024 -SCFI-2013

 

 

 

© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1110A10- Page 

1

 sur 

-

 

Ed. 06/04/2022 

STid reserves the right to make change without notice, for the purpose of product improvement.

 

 

 

 

 
 
 

Product references 

 

 

Outputs cable: 3 m  

 

                             

 

       

A

                               

B

 

 

 

Connector  Output cable 

Type 

Wiegand  Clock & Data  RS485 

Brown 

0 Vdc 

 Red 

+Vcc (+9 Vdc to +15 Vdc) 

Grey 

D0 

Code 

NC 

Blue 

D1 

Data 

L+ 

Yellow 

Clock 

Clock 

L - 

Green 

Led 1 

Orange 

Led 2 

White 

Buzzer 

Power supply characteristics 

Use an AC/DC power supply type LPS, Limited Power Source (as per IEC/UL/EN 60950-1 Ed2) or type ES1, PS1 (according to IEC/UL/EN 62368-1) for the main supply. 
 
Main power supply:   

Range: +9 Vdc to +15 Vdc 

 

Typical: 12 Vdc 

Max. consumption at 12 Vdc: 

ARC1-XY: 130 mA 

ARC1S-XY /PH5: 140 mA 

ARC1S-XY /BT1: 150 mA 

MA1-XY: 130 mA 

MA1S-XY /PH5: 140 mA 

MA1S-XY /BT1: 150 mA 

 

Characteristics  

Communication:  

RS485 (L+ & L-) / TTL (Wiegand / Clock and Data) 

Connector output:    - 8 female stamped crimp terminals 28-22AWG (Wurth Electronik 62400113722DEC) 

 

- 8 points female dual-row terminal housing (Wurth Electronik 624008213322) 

(use Crimp Hand Tool 

WURTH ELEKTRONIK 

600624228220) 

Cable output:  

TRANXALARM - 8x0,22mm

2

 

 Length 3.05m 

Protection:   

IP65 classified reader 

 

Buzzer / LED 

The operating mode for the Buzzer and LED 1 and 2 can be programmed by a configuration card (SCB / OCB) or controlled by the remote system with a 0 Vdc 

respectively on the 

Led 1

”, “

Led 2

” and “

Buzzer

” inputs of the reader’s connector or controlled by the 

communication protocol of the reader (SSCP

®

 / OSDP

TM

). 

 

Anti-tearing 

Tearing is detected by an accelerometer. When the reader is wrenched: 

 

for R/S 31: the wrenching signal will be emitted on the “Data/Data1”

 line. This function is configurable via a configuration card. 

 

for R/S 33 and OSDP

TM

: the reader will perform the operations configured with the configuration card. 

 

for W33: the reader will perform the operations configured with the SSCP

®

 protocol. 

Caution: switch on the reader when it is in its final position to initialize the accelerometer in the correct position.

 

Read-only reader configuration  

R and S readers are configurable with SCB RFID / Virtual configuration card. 
OSDP

TM

 readers are configurable with OCB RFID / Virtual configuration card or with FileTransfer command. 

 

If the SCB/OCB is compatible with the reader’s firmware, the LED lights green and the buzzer beeps five times.

 

 

If the SCB/OCB is not compatible with the read

er’s firmware, the LED lights red and the buzzer is activated for 1

 s. 

 

If the SCB/OCB key is different from the reader’s key: no reaction.

 

Caution: set your reader with your own company key. 

 

Powering-up the readers  

On power-up, the reader enters an initialization phase: 

1.

 

Activation of the white LED and buzzer for 100 ms. 

For read-only readers and OSDP

TM

 readers: 

2.

 

Activation of the LED, according to the color code: Red = +10, Orange = +5, Green = +1, indicating the firmware version.  

3.

 

For serial R/S reader only: the orange LED flashes 20 times: waiting for an update. 

4.

 

For Bluetooth

® 

reader only: Activating white fixed LED during Bluetooth initialization. 

5.

 

Activation of the default LED (read-only: flashes blue, OSDP

TM

: off; if no customer specific configuration). 

 

 

Caution for Bluetooth reader  

Caution: at the reader Bluetooth (BT1) powering, make sure that nothing is in an area of at least 10 cm / 3.94 in. around the reader (ex. No hand in front 

of the reader…).

 

TBLOCK option 

Connection 

Press the orange part to open. 

Insert the wire. 

Release the orange part. 

Check that the wire is correctly clipped. 

 
 
 
 
 
 
 
 
 
 

Precautions for installation 

 

The s

upply voltage at the reader’s connector should be b

9 Vdc and +15 Vdc. 

 

As far as possible, keep the reader away from computer or power source cables. They can generate electrical interference, depending on their radiation level and 

the proximity of the reader. 

 

Recommended distance between two readers: parallel plane: 15.8 in 

 same plane: 15.8 in 

 perpendicular plane: 11.8 in.

 

 

 

Recommended distance between two Bluetooth

®

 

readers: 2 meters / 78.74 inch either plan. 

 

Place the reader at a height of less than 2 meters / 78.74 inch (standard UL/IEC 62368). 

 

If the reader is fixed on a metal surface, it is possible to have a reduction in the reading distance.  

 

Use a ferrite (two-way) for the cable (power supply and data). 

Example: reference 74271222 WURTH ELEKTRONIK

 

By design, the reader can be installed indoors and outdoors. 

 

BEFORE powering on, connect the wires or the connector of the reader. Before disconnecting the wires or the connector of the reader, power off. 

 

Operating temperature:   -4 °F to 158 °F / -20°C à +70°C. 

 

ARC1-XY 
ARC1S-XY/PH5 

ARC1S-XY/BT1 

MA1-XY 
MA1S-XY/PH5 

MA1S-XY/BT1 

X: 
 

1: TTL Output 
3:  RS485 Output 

Y:     
 

A: cable 
B: cable with connector 

Reader 

 Host 

0.94 in 

1.3

4

 in

 

US 

FR 

ES 