Cooling and Ventilation
All FLX-E amplifiers are convection cooled. Do not block the ventilation holes or slots. Use the following
chart to determine cooling requirements for your application.
Operating Conditions
Power consumption
(W)
Power
dissipated (W)
Energy
dissipated(BTU/hr)
Idle (operational, no input signals)
12
12
41
1/8 rated audio power
60
20
68
Power consumption and energy dissipated
Ensure that there is sufficient open space around the amplifier to allow for free air flow. Please follow the
open space requirements on the following page to ensure adequate ventilation when installed in a cabinet.
When mounted in an equipment rack, the amplifier is designed to have air pulled into the amplifier from
the front vent holes and exhausted through the rear vents. It is recommended to leave a 1RU rack space
between amplifiers or other devices with significant power dissipation.