2.5.3
Safety system of the lift against overloading
The lifts have following safety features:
• Hydraulic overload protection.
- Hose burst valves, which shut off the cylinders in the event of hose rupture.
- A pressure relief valve, which prevents the construction from being overloaded.
• An electro-pneumatic-mechanical fall prevention system (safety catches), which
mechanically stops the lowering movement in the event of power failure.
• An operating system with "hold to run" type.
These features assure a safe operation without the possibility of overloading the lift.
2.5.4
Lighting fixture
The lighting fixture is suitable for use in Class 1, Div 2 group D, or unclassified
locations.
Warning
w
Sealed components. Exposure to some chemicals may degrade the sealing
properties of materials used in the lighting fixture.
Warning
w
Explosion hazard. Do not disconnect while the circuit is live or unless the area is
known to be free of ignitable concentrations.
Figure 2.1
Lighting fixture