Installation and Service Manual
36
SK 2055 / 2070 / 2090
11. If desired, the perimeter of the base plates can now be sealed with silicone
mastic.
5.1.4 Assembling the hydraulics and electricity
Take care when fitting hydraulic components. All components must be free of
dirt. Use clean UNIL SX 15 oil for the hydraulic system, filtered at a maximum of
4 microns.
1. Remove the hydraulic unit housing (the housing is secured by two safety
bolts).
2. Measure the distance between the fixture points for the overhead wiring in
the posts and adjust the horizontal connecting tube (1) to the correct length,
if necessary.
1
2
2
3
1. Horizontal tube
2. Vertical tube with bend
3. Support
Summary of Contents for Freedomlift SK 2055
Page 108: ...Installation and Service Manual 108 SK 2055 2070 2090 14 2 Electrical diagram 3 x 230V ...
Page 109: ...Installation and Service Manual 109 SK 2055 2070 2090 14 3 Electrical diagram 3 x 400V ...
Page 113: ...Installation and Service Manual 113 SK 2055 2070 2090 14 6 Dimensions SK 2055 3 piece arms ...