INSTALLATION INSTRUCTIONS

WARNING:

  TO AVOID FIRE, SHOCK OR DEATH, TURN OFF AND LOCKOUT POWER BEFORE PERFORMING ANY MAINTENANCE.

CAUTION:

  

THIS FIXTURE MUST BE WIRED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL 
CODES. PROPER GROUNDING IS REQUIRED. ALL WORK SHOULD BE DONE BY A QUALIFIED ELECTRICIAN.

For 2100mA Driver with Synjet Only

 

Open roof and remove all reflectors and sockets. 

Remove bottom hex nut and lock washer from 

Synjetassembly and insert pipe nipple and leads 

through the hole in the center of the fitter and 

into fitter chamber. Tighten in place with nut and 

lockwasher.   

NOTE:

 If the hole in the center of the fitter is not 

present, it may be added using a 21/32”, 11/16”, 

or 17mm drill.

Lean the bracket forward toward the fitter opening to allow the locking tab to enter the right 

side of the fitter where the roof is lower.  Slide the bracket to the left and twist to engage 

the driver against the front left wall and tighten the thumb screw to restrict movement of 

the assembly. 

Unpack the 1843-XRLED CONVERSION KIT. Handle with care. Do not touch the optics.  

Recycle the empty packaging.

Remove the mounting screws 

(retain them) on the fitter door 

and pull out the door and at-

tached ballast. Disconnect supply 

lines and fixture leads. Detach the 

ballast from the door by remov-

ing two mounting screws. The 

ballast will not be required for the 

conversion.  

Note:

 Most 250W HID configura-

tions have the ballast in a remote 

location. These ballasts should 

also be removed.

LED Module

LED Bracket Assembly

Driver Assembly Bracket

SYNJET Assembly  

(For 2100mA Driver)

STEP