Micro Series Water Temperature Control Units 

Reference Manual (PN: 682.89373.00) for 

Complete Operation and Installation Instructions 

(Available online at www.sterlco.com)

 

 

Sterling, Inc. 

Part No:  682.92594.10 

2900 S. 160

th

 Street · New Berlin, WI 53151 · USA   

 

 

 

Bulletin No: HC2-320 

Tel. 262.641.8610 • Fax 262.641.8653 
 

 

 
 

Quickstart Installation Checklist 

(Refer to main manual for complete installation instructions). 
 

1.  Connect 3-phase power based on nameplate data. 
2.  Install properly sized plumbing between temperature control unit 

and primary processing equipment (supply and return).  

3.  Install properly sized plumbing between temperature control unit 

and cooling water supply and return. Cooling water supply must be 
at least 16 psi (110 kPa/1.1bar) for a 250˚F (121°C)

 

configuration 

and 55 psi (379 kPa/3.8bar)

 

for a 300˚F (149°C) configuration.  

4.  Ensure proper pump rotation. (The pump should be moving 

clockwise while looking at the motor end). 

 
 

 
 

Unit Operation 

(Refer to main manual and controller manual for complete operating instructions). 
 

Start Up 

1. Push 

the 

ON/OFF

 rocker switch to the 

ON ( | ) 

to energize the unit and begin the temperature control cycle. 

The switch will be illuminated whenever the unit is on.  

2.  The unit will automatically vent for approximately one minute. 
3.  If needed, press and hold the vent button to purge any additional air from the process loop. 
 
4.  Set process temperature (

PV

) by pressing the         

Up Arrow 

or         

Down Arrow

 keys.  

Shut Down 

1.  Adjust set point below 150˚ F (66˚ C). 

Allow unit to stabilize. 

2.  Push ON/OFF rocker switch to the OFF               

( 0 ) position to de-energize the unit. 

 
 

Standard Controller 

Summary of Contents for Water Heater

Page 1: ...y must be at least 16 psi 110 kPa 1 1bar for a 250 F 121 C configuration and 55 psi 379 kPa 3 8bar for a 300 F 149 C configuration 4 Ensure proper pump rotation The pump should be moving clockwise while looking at the motor end Unit Operation Refer to main manual and controller manual for complete operating instructions Start Up 1 Push the ON OFF rocker switch to the ON to energize the unit and be...

Page 2: ...0 for Complete Operation and Installation Instructions Available online at www sterlco com Sterling Inc Part No 682 92594 10 2900 S 160th Street New Berlin WI 53151 USA Bulletin No HC2 320 Tel 262 641 8610 Fax 262 641 8653 Spare Parts Location See next page for Spare Parts List ...

Page 3: ...726 00270 02 726 00267 02 726 00265 02 9 kW 3 req d 722 00128 05 722 00128 06 722 00130 02 2 9 kW contactor 726 00270 02 726 00268 02 726 00268 02 Motor Pumps 230 3 60 460 3 60 575 3 50 HP 0 37 kW 075 00915 00 250 F 121 C 075 00915 00 250 F 121 C 075 00915 02 250 F 121 C HP MCP 726 00304 02 726 00303 02 726 00302 02 HP 0 56 kW 075 00856 00 250 F 121 C 075 00856 00 250 F 121 C 075 00856 02 250 F 12...

Page 4: ...buildup Clean mold Quick disconnect fitting with check valve Remove and replace fitting or valve Temperature fluctuations rapid cycling from hot to cold Lime buildup in unit piping Clean or replace Drain is plugged or excessive back pressure is in drain line Clear drain line or eliminate back pressure condition Faulty solenoid valve Test solenoid valve by pressing VENT button and listen for valve ...

Reviews: