HEPA Air Scrubber

 (HEPAPro AS800)

The HEPAPro AS800 is a compact, portable HEPA Air Scrubber for abatement, resto-

ration, and construction projects.  It is commercial, yet lightweight machine that is 

easy to carry, transport and store.  The unit has a 22” x 24” footprint, stands only 14” 

tall and weighs less than 35 lbs. 

HEPAPro AS800 offers variable airflow, up to 800 CFM, that can be directed both 

vertically or horizontally.   It accepts a 16” inlet flex duct and a 10” lay flat outlet duct.  

The unit operates at less than two amps of power.  It is capable of providing 4 air 

changes per hour (the recommended minimum) in a 7500 cubic foot room (more 

than a 30’ x 30’x 8’).

This HEPA air scrubber offers a 2-stage filter design including a tested and certified 

HEPA filter and pleated pre-filter.  An optional carbon/potassium permanganate 

filter is available to absorb a wide range of odors and gases.

Warning To Avoid Electric Shock

•  Do not expose to standing water or rain.
•  Connect to GFCI outlet.
•  Do not use an extension cord.
•  Unplug fan before servicing or changing filters.
•  Do not block air intake or outlet.  Allow minimum of 12-inches of distance between obstructions.
•  Indoor use only.
•  Do not use as stool or bench.
•  Do not operate with damaged cord or plug.

Electrical Requirements

HEPAPro AS800 should be plugged into a grounded 15 amp circuit. Unit draws about 2 amps with clean filters and no 

ducting. The amp draw will decrease slightly with added ducting and as the filters load with particulate. Due to the pres

-

ence of GFCI receptacle, the HEPAPro AS800 must be plugged directly into a wall outlet. No extension cords should be 

used.

Summary of Contents for HEPAPro AS800

Page 1: ... including a tested and certified HEPA filter and pleated pre filter An optional carbon potassium permanganate filter is available to absorb a wide range of odors and gases Warning To Avoid Electric Shock Do not expose to standing water or rain Connect to GFCI outlet Do not use an extension cord Unplug fan before servicing or changing filters Do not block air intake or outlet Allow minimum of 12 i...

Page 2: ...ler fan may not start on the low speed setting If this occurs rotate the speed control to high speed until the impeller fan starts then adjust it to a lower speed Resettable Circuit Breaker The 12 AMP thermal resettable circuit breaker protects the unit and devices connected to its duplex GFCI outlet The circuit break er is designed to sense the total current draw through the circuit The circuit b...

Page 3: ...e the pre filter and run on high again If the light remains illumi nated it is time to replace the HEPA filter The life of the optional Activated Carbon Potassium Permanganate Filters depend on the hours used and the level of contaminants recovered The activated carbon removes the heavier volatile organics while the potassium permanganate removes lower molecular weight contaminants such as smoke o...

Page 4: ...arranties expressed or implied including but not limited to the warranties of merchantability of fitness for a particular purpose The remedy provided in this warranty is exclusive and is granted in lieu of all other remedies Some states do not allow limitations on how long an implied war ranty lasts so the above limitation may not apply to you In no event will Sterling be liable for loss of use of...