1
Installation and Operation Instructions
NOTE: Read this entire instruction sheet before starting the installation.
I
MPORTANT
C
ONSIDERATIONS
Improper installation, adjustment, alteration, service,
maintenance, or use can cause fire, electrical shock, or
other conditions which may cause personal injury or
property damage. Consult your supplier or Steril-Aire for
information or assistance.
Understand the signal words
DANGER
,
WARNING
, a n d
CAUTION
. These words are universally used for overall
safety.
DANGER
identifies the most serious hazards which
will result in severe personal injury or death.
WARNING
signifies hazards which could result in personal injury or
death.
CAUTION
is used to identify unsafe practices
resulting in minor personal injury or product and property
damage.
WARNING:
Before performing maintenance or service on fixture,
ensure unit is unplugged. Electrical shock can cause
injury or death.
CAUTIONS:
•
Never expose eyes or skin to UVC light. Wear gloves,
face shield/glasses (per ANSI Z87.1) and cover all
exposed skin.
•
Do not touch UVC Emitter
®
germicidal lamp without
gloves. Damage to Emitter may result. Oil from
fingerprints will permanently etch glass of Emitter and
weaken structure. If necessary, clean Emitter using a
Steril-Aire cleaning kit, isopropyl alcohol and a lint-free
wipe may be substituted.
•
UVC Emitters are fragile. To prevent accidental
breakage handle the UVC Emitter with care.
•
Voltages outside of the range designed for the unit
will void the warranty and do permanent damage to
the entire unit.
•
Emitter contains a small quantity of mercury.
If an Emitter breaks, clean and dispose of with the
same care as a fluorescent lamp.
•
UVC energy may cause damage to non-metallic
components. Such components shall be protected
with UV resistant material such as aluminum foil,
aluminum duct tape, metallic shields, etc.
•
The qualified installer or agency must use factory
kits and accessories when installing this product.
For your safety ensure that the Kit is electrically
connected to a proper power source, on/off switch,
interlock switch (or control panel) and fuse.
Upon completing the installation, the UVC Emitters
should be operated continuously, 24/7, to preclude
the development of mold and bacteria.
Dispose of used Emitters in accordance with local
regulations regarding the disposal of fluorescent
lamps.
Enhanced UVC Kit
Part Number: 10000180-1
Patents 5,817,276/ 6,245,293/ 6,267,924/ 6,280,686/ 6,313,470/ 6,423,882/ 6,500,267
/6,589,476/ 6,627,000/ 6,783,578/
7,140,749/ 7,282,728/ 7,459,694 & others pending
Made in the USA