HEATER RESET
The heater on the S90 pasteuriser has 2 manual reset safety thermostat. To reset the
thermostat follow this procedure:
1
st
Thermostat
•
Ensure the power is off
•
Remove the front panel of the pasteuriser
•
Remove the right hand side panel
•
The picture below shows the side view with the heater highlighted
•
The cap of the heater is held on
with a nut. Remove
the nut and the cap.
•
Inside the cap the thermostat is visible. The photo below shows the thermostat
with the reset button highlighted. The reset button is the small rectangular button
at the top. Press the button to reset.
•
Replace the heater cap.
Heater Cap
(At bottom ofHeater)