Shanghai STEP Electric corporation
B-
14
List
s of
Function Parameters
, Runnin
g
-st
atus and Fault
s
Function
Code
Name
Content
Range
Unit
Default
Remarks
检测制动单元标志
K36
BrakingUnit Flag
Whether to check the
braking unit at first power
on
0: no checking
1: checking
0 / 1
×
1
故障自动复位次数
K37
Auto Reset Times
Auto reset times
0
~
10
次
3
编码器断线保护阀值
百分比值
K39
PGO Action
When given the speed
of the motor rated
speed is less than
K39, the 12 fault
discrimination does not
work, only the effective
induction motor
0
~
10
%
2
B.2 Running Status List
Function
Code
Name
Content
Range
Unit
Default
Remarks
反馈速度
U00
Feedback Speed
Monitor feedback speed of
the motor, in rpm.
× rpm
×
指令速度
0
U01
Ref. Speed 0
Monitor the speed given by
motor command, in rpm.
× rpm
×
指令速度
1
U02
Ref. Speed 1
Monitor the speed given by
motor command after
filtering, in rpm.
× rpm
×
速度偏差
U03
Speed Deviate
Monitor the difference
between feedback speed
and the speed given by the
command, in rpm.
× rpm
×
输出电流
U04
Output Current
Monitor Inverter output
current, in A.
× A ×
力矩偏置
U05
Torque Offset
Monitor servo output torque,
in %.
× % ×
输出力矩
U06
Output Torque
Monitor torque output under
vector control, in %.
× % ×
直流母线电压
U07
DC BUS Voltage
Monitor DC voltage of the
Inverter internal main circuit,
in V.
× V ×
AI1
输入电压
U08
Ai1 Voltage
Monitor analog voltage input
1, in V.
× V ×