StelproXleratorManual.doc
FOR PROPER ELECTRICAL CONNECTIONS, CHECK YOUR LOCAL BUILDING CODES.
YOUR UNIT MUST BE INSTALLED BY A QUALIFIED, LICENSED ELECTRICIAN.
INSTALLATION INSTRUCTIONS FOR
STELPRO
XLERATOR
®
HAND DRYER
(SHDXL SERIES)
1. Remove cover of dryer by unscrewing two tamper-proof bolts from the sides of the cover with the special wrench provided with each unit.
2. Attach wall plate at the four corners to smooth wall. In locations where vandalism is a concern, use the two additional mounting holes shown.
Remove control assembly to access right side mounting hole. Attach with the following recommended type of fastener (see above).
3. Connect a 110/120V dryer to a 15 Amp. branch circuit using at least 12 GA copper wire. (Do not exceed a 20 Amp. Branch circuit)
Connect a 208 or 220/240V dryer to a 15 Amp. branch circuit using at least 14 GA copper wire. (Do not exceed a 15 Amp. Branch circuit)
4. Attach lines to terminals as indicated by the schematic inside dryer cover. Be sure that an equipment ground wire is securely fastened to green
ground screw on base plate. For runs over 50 feet or for multiple installations, increase the size of the wire used. Dryers located in shower rooms or
other wet locations should be installed with circuits protected by ground fault interrupter(s).
5. In multiple installations, before replacing cover, check the Serial Number marked inside the dryer to be sure it matches the Serial Number marked
on the label at the bottom of cover.
PLEASE DO NOT SWITCH COVERS.
PARTS LIST FOR XLERATOR DRYER
Suggested Mtg. Heights from floor
to bottom of dryer
)
m
c
9
0
1
(
“
5
4
s
’
n
e
M
Ladies’
43“ (104 cm)
Teenagers’
41“ (99 cm)
Sm. Children
35“ (84 cm)
Handicapped
37“ (89 cm)
IF MOUNTING OVER COUNTERTOP, DISTANCE FROM
COUNTER TO DRYER MUST BE 15” (381mm)
MINIMUM
Recommended Fastener
Masonry Wall
½” expansion sleeve with ¼” lag bolt
Hollow Wall
¼” wing type through bolt
Wooden Wall
¼” lag screw with washer
NOTE
TO PROTECT DRYER FROM INTERNAL CORROSION CAUSED BY WASH WATER AND CLEANING SOLUTIONS, IT IS HIGHLY RECOMMENDED
THAT AFTER COMPLETING INSTALLATION, A BEAD OF SILICONE SEALANT BE PLACED AROUND THE OUTSIDE OF THE COVER AT THE WALL.
REF NO.
DESCRIPTION
XL 1
Cover (includes Nameplate)
XL 2
Nameplate
XL 3
Tamper-proof Bolt
XL 4
Tamper-proof Wrench
XL 5
Air Outlet (includes gasket
& screws)
XL 6
Terminal Block (includes
screws)
XL 7
Control Assembly & Sensor
XL 8
Heating Element Assembly
XL 9
Motor Assembly (includes
gaskets & wire harness)
XL 10
Wall Plate Assembly
(includes mtg. brackets)
XL 11
Cover Mounting Brackets
XL 12
Housing Grommet
XL 13
Housing Retainer
XL 14
Recess Kit (for ADA)
XL 15
Optics (Sensor)
LOCATION OF ADDED MTG HOLES
FOR MORE SECURE INSTALLATION
(SEE NOTE 2 BELOW)