MAINS VOLTAGE
The generator works at mains voltages differing by 20% from the rated mains value
(rated voltage 230V, minimum voltage 185V, maximum voltage 275V).
SUPPLY BY MOTOR GENERATOR
The generator is designed to work supplied by generating sets.
1) - The 230V a.c. auxiliary socket must be able to supply suitable power as
indicated in the section (electrical characteristics listed in paragraph 2.2).
2) - The auxiliary socket of the generating set must satisfy the following conditions:
- peak voltage of the a.c. wave lower than 423V a.c.
- frequency of the a.c. wave between 50 and 60Hz.
- RMS voltage of the a.c. wave higher than 180V c.a.
It is important for the generating set to satisfy the conditions listed in points1 and 2.
It is recommended not to use this machine with generating sets that do not respect
these conditions because it could be damaged.
CONNECTION
- Before making the electrical connections between the current generator and the
line switch, ensure that the switch is turned off.
- The distribution panel must comply with the regulations in force in the country of
use ( ).
- The mains system must be of the industrial type.
- The multipolar cable is provided with a type G32 plug (Schuko) complying with
standard UNI 47 166/68.
Provide a special socket, model SCHUKO 16A , which can receive leads with a
section of 2.5mm².
MODEL
VOLTAGE/PHASES
DELAYED FUSE
MIGGY 161
1 phase 230V
16 A
TECHNICAL DESCRIPTION
ENGLISH
79
MIGGY 161
COD. 6908300020
STEL s.r.l.
– Via del Progresso n° 59 – 36020
Loc. Castegnero (VICENZA) - ITALY
TEL. +39 444 639525 (central.) – +39 444 639682 (comm.)
FAX +39 444 639641 – E-mail: stel @ stelgroup.it
http: www.stelgroup.it
6.3- AUSSETZZYKLUS (ED) UND ÜBERTEMPERATUR
Unter Aussetzzyklus versteht man den Prozentsatz von 10 Minuten, den der Bediener beim
Schweißen aussetzen muss, um zu vermeiden, dass der Generator aufgrund von Übertemperatur
ausfällt.
Wenn die Maschine wegen Übertemperatur ausfällt, beginnt die gelbe Led
(Bez. 3 Seite 8
) zu leu-
chten.
Es ist nun erforderlich, 10 Minuten abzuwarten, bevor man das Schweißen wieder aufnimmt.
Der Ausfall ist reversibel. Um weitere Eingriffe der Schutzeinrichtung zu vermeiden, ist es erfor-
derlich, entweder die Amperezahl oder, nach dem Wiederaufnehmen des Schweißens, die
Schweißzeit herabzusetzen.
DEUTSCH
ABBILDUNGEN
10 minuti
Saldatura continua
100% ED (ciclo intermittenza)
4 minuti saldatura
10 minuti
6 minuti attesa
10 minuti
40% ED (ciclo intermittenza)
MAX
5
65
A
MIN
MAX
Cod.6601630000
A
+
+
+
t2
Cod. 6603660000
MIN
MAX
V
2T
4T
2T
MIG
ON
OFF
MIN
MAX
MIN
MAX