current water temperature and the desired water temperature, it can take several
days until the desired water temperature is reached.
• If do not use the pool for more than a week, shut off the heat pump or reduce the set
water temperature.
• Do not use the heat pump when the ambient temperature falls below 5 °C.
• Use the timer (see "Operation" section) instead of running the heat pump
continuously in operating mode.
• Cover the pool to prevent heat loss due to wind.
Temperature sensors
The heat pump has four temperature sensors that measure the following temperatures with an accuracy
of ±3 °C:
- (
14
) current water temperature
- (
15
) ambient temperature
- (
16
) temperature of the compressor in the finned heat exchanger
- (
17
) temperature of the condenser in the finned heat exchanger
The temperature display can be called up during the operating mode and shows the temperatures
measured by the temperature sensors.
Active display elements:
- The
Heating
indicator
20
or the
Cooling
indicator
19
is lit.
- The
Temperature 2
display
21
shows the set water temperature in °C.
- The
Temperature 1
display
24
shows the selected temperature sensor (
14
–
17
).
• Note: (
18
) can be selected, but is not in use
- The
SET/TEMP
indicator
26
is lit.
I
26
24
20
21
41
en
Summary of Contents for Waterpower 8500
Page 2: ......
Page 3: ...1 2 3 4 5 3 de...
Page 4: ...C B A C 10 6 7 8 9 12 5 11 18 17 16 15 14 13 26 25 24 19 20 21 22 23 4...