14
STEIN300_Radius Circuit_06_GB.doc / 01.2020
5.3
Radius circuit installation and de-installation
i
For the replacement of the radius circuit if it is defective or conversions where it is re-
moved.
Protective clothing must be worn!
Wear your personal safety clothing: Safety footwear and safety gloves.
WARNING!
Remember that the radius circuit is very heavy!
Use suitable equipment, such as a fork-lift truck, to transport and install the radius cir-
cuit.
De-installation
Fig. 5-1:
Example:
180° radius circuit seen
from below
1
Belt element
2
Base plate
3
Module connecting
screws
4
Stand connecting
screws
i
In the following section the radius circuit and stand base assembly are together called
module.
Place a protective mat the size of the radius circuit onto the floor.
This avoids the radius circuit getting damaged.
Fit support sections to the relevant belt element so that it is held up once the module
has been removed.
Unscrew the connecting screws in the belt element (3).
Remove the module from the belt element with the aid of suitable lifting gear or
through help from assistants.
Place the module onto the protective mat so that the underneath of the radius circuit
is on top.
Unscrew the stand connecting screws (4).
1
2
3
4