background image

E

n

g

lis

h

(G

B)

 

Note

   

 

Spare

 

parts

 

and

 

accessories

 

not

 

supplied

 

by

 

Caution

  

 

Pumps

 

that

 

have

 

been

 

used

 

for

 

radioactive

 

liquids

 

Note

   

 

The

 

safety

 

declaration

 

must

 

be

 

included

 

with

 

the

 

 

14.

 

Service

 

 

Warning

 

Observe

 

local

 

regulations

 

for

 

safety,

 

health

 

and

 

environment.

 

Contact

 

Steffens

 

or

 

an

 

authorised

 

service

 

workshop

 

if

 

you

 

cannot

 

remedy

 

faults

 

yourself.

 

Please

 

provide

 

an

 

exact

 

description

 

of

 

the

 

problem

 

so

 

that

 

our

 

service

 

technician

 

can

 

prepare

 

and

 

provide

 

the

 

appropriate

 

spare

 

parts.

 

The

 

technical

 

data

 

can

 

be

 

found

 

on

 

the

 

pump

 

nameplate.

 

Please

 

state

 

these

 

pieces

 

of

 

information

 

if

 

you

 

request

 

service:

 

 

Pump

 

number

 

and

 

type

 

designation

 

(punched

 

on

 

the

 

nameplate)

 

or

 

the

 

order

 

number.

 

 

Note

 

 

Product

 

number

 

and

 

type

 

of

 

spare

 

part

 

(see

 

sectional

 

drawings

 

of

 

the

 

pumps

 

and

 

tables

 

of

 

spare

 

parts).

 

 

Desired

 

method

 

of

 

shipment

 

(freight,

 

express

 

or

 

mail).

 

The

 

shipping

 

costs

 

will

 

be

 

charged

 

to

 

the

 

sender.

 

In

 

case

 

of

 

petrol

 

or

 

diesel

 

engine

 

faults

 

occurring

 

after

 

expiration

 

of

 

the

 

warranty

 

period,

 

we

 

recommend

 

that

 

you

 

send

 

the

 

engine

 

to

 

the

 

nearest

 

service

 

centre

 

of

 

the

 

engine

 

supplier.

 

See

 

the

 

operating

 

instructions

 

for

 

the

 

engine.

 

14.1

 

Spare

 

parts

 

A

 

complete

 

list

 

of

 

spare

 

parts

 

is

 

available

 

in

 

the

 

service

 

kit

 

catalogue.

 

See

 

www.steffens-pumpen.de.

 

 

Steffens

 

are

 

not

 

tested

 

or

 

certified

 

by

 

Steffens.

 

The

 

installation

 

and/or

 

usage

 

of

 

such

 

products

 

may

 

in

 

certain

 

cases

 

change

 

and

 

impair

 

the

 

properties

 

of

 

the

 

pump.

 

Steffens

 

cannot

 

be

 

held

 

liable

 

for

 

any

 

damage

 

caused

 

by

 

the

 

use

 

of

 

non-original

 

spare

 

parts.

 

14.2

 

Contaminated

 

pumps

 

If

 

a

 

pump

 

has

 

been

 

used

 

for

 

a

 

liquid

 

which

 

is

 

injurious

 

to

 

health

 

or

 

toxic,

 

it

 

will

 

be

 

classified

 

as

 

contaminated.

 

If

 

Steffens

 

is

 

requested

 

to

 

service

 

the

 

pump,

 

Steffens

 

must

 

be

 

contacted

 

with

 

details

 

about

 

the

 

pumped

 

liquid,

 

etc.

 

before

 

the

 

pump

 

is

 

returned

 

for

 

service.

 

Otherwise

 

Steffens

 

can

 

refuse

 

to

 

accept

 

to

 

service

 

the

 

pump.

 

 

will

 

not

 

be

 

accepted

 

under

 

any

 

circumstances.

 

 

service

 

request.

 

Steffens

 

products

 

and

 

their

 

parts

 

will

 

only

 

be

 

inspected/repaired

 

if

 

the

 

safety

 

declaration

 

has

 

been

 

correctly

 

and

 

completely

 

filled

 

out

 

by

 

authorised

 

and

 

qualified

 

staff.

 

However,

 

we

 

still

 

reserve

 

the

 

right

 

to

 

refuse

 

to

 

accept

 

a

 

request

 

for

 

other

 

reasons.

 

15.

 

Disposal

 

This

 

product

 

or

 

parts

 

of

 

it

 

must

 

be

 

disposed

 

of

 

in

 

an

 

environmentally

 

sound

 

way:

 

1.

 

Use

 

the

 

public

 

or

 

private

 

waste

 

collection

 

service.

 

2.

 

If

 

this

 

is

 

not

 

possible,

 

contact

 

the

 

nearest

 

Steffens

 

company

 

or

 

service

 

workshop.

 

 

Subject

 

to

 

alterations.

 

 
 
 
 
 
 
 

 

11

 

Summary of Contents for Pomona

Page 1: ...Steffens Pumpen Fachhandel GmbH Hengsterberg 13 D 33129 Delbrück Telefon 05250 99879 0 Original User Manual for Pomona Pumps Pomona Installation and operating instructions Montage und Betriebsanweisung ...

Page 2: ......

Page 3: ...Tableofcontents POMONA English GB Installation and operating instructions 4 Deutsch DE Montage und Betriebsanleitung 12 Appendix 21 Declaration of conformity 23 Konformitätserklärung 24 3 ...

Page 4: ... 9 11 1 Lubrication 9 11 2 Shaft seals 9 11 3 Motor bearings 9 11 4 Roller bearing grease 9 12 Frost protection 9 13 Fault finding 10 14 Service 11 14 1 Spare parts 11 14 2 Contaminated pumps 11 15 Disposal 11 codes of good practice Warning The use of this product requires experience with and knowledge of the product Persons with reduced physical sensory or mental capabilities must not use this pr...

Page 5: ...troke diesel engine 4 stroke petrol engine Special version Frame Without frame Base frame Carrying frame Trolley Impeller Cast iron GG Cast bronze G CuSn Special version Sealing NBR FKM Viton Special version Fig 2 Correct lifting of motor and pump on base frame 15 Motor power P2 100 W Motor 1 3 X 1 phase 220 240 3 phase 220 240D 380 415Y Special version 4 1 Coupling Flexible coupling with bearing ...

Page 6: ... G CuSn If the tank is to be emptied drain the fuel into a suitable container 6 Pumped liquids Connections Suction and discharge connections G 3 4 G2 G3 G4 DN 20 DN 50 DN 80 DN 100 The pumped liquid must not attack the pump materials chemically pH value 4 10 POMONA pumps are wear resistant and not sensitive to contamination from mud dirt or sand abrasive materials such as river sand Solid matter u...

Page 7: ...foundation must have an absolutely level and even surface The foundation should always be 200 mm longer and wider than the pump 100m m 100m m Fig 3 Minimum size of the concrete foundation In installations where low noise operation is particularly important we recommend a foundation with a weight up to five times that of the pump Dimensions of base frame Check the equipment for transport damage Fit...

Page 8: ... 3 Starting the pump The electrical installation should be carried out by an authorised person in accordance with local regulations and the wiring diagram in the terminal box cover Caution Do not start the pump until it has been filled with liquid The pump must not run against a closed discharge The pump must be fused in the building s electrical installation and be connected via an external switc...

Page 9: ...netrating into the ground Note that the motor must meet safety regulations Petrol and diesel engines should be maintained according to the manufacturer s instructions 11 2 Shaft seals Shaft seals are maintenance free and work with practically no leakage In the event of heavy or increasing leakage the shaft seal must be inspected 11 4 Roller bearing grease Basis lithium loaded temperature range 20 ...

Page 10: ...r motor Check the setting Replace the motor protective circuit breaker if defective Check the electrical connection Replace the fuse if defective 3 Pump too noisy Pump does not run a Suction head too large Increase the liquid level on the suction side Completely open the isolating valve on the suction side smoothly and vibrates b Air in the suction pipe or pump Vent and fill the suction pipe and p...

Page 11: ... engine 14 1 Spare parts A complete list of spare parts is available in the service kit catalogue See www steffens pumpen de Steffens are not tested or certified by Steffens The installation and or usage of such products may in certain cases change and impair the properties of the pump Steffens cannot be held liable for any damage caused by the use of non original spare parts 14 2 Contaminated pum...

Page 12: ...ger 25 11 4 Wälzlagerfett 25 12 Schutz vor Frosteinwirkung 25 13 Störungssuche 26 14 Instandhaltung 28 14 1 Ersatzteile 28 14 2 Kontaminierte Pumpen 28 15 Entsorgung 28 der Technik erfolgen Warnung Die Benutzung dieses Produktes erfordert Erfahrung und Wissen über das Produkt Personen die in ihren körperlichen geistigen oder sensorischen Fähigkeiten eingeschränkt sind dürfen dieses Produkt nur ben...

Page 13: ...romotor 50 Hz Elektromotor 60 Hz 4 Takt Dieselmotor 4 Takt Benzinmotor Sonderausführung Rahmen Ohne Rahmen Grundrahmen Tragrahmen Fahrbares Gestell Laufrad Grauguss GG Bronzeguss G CuSn Sonderausführung Dichtung NBR FKM Viton Sonderausführung 15 Motorleistung P2 100 W Motor Abb 2 Richtiges Anheben eines kompletten Pumpenaggregates mit Motor und Grundrahmen 1 3 X 1 phasig 220 240 3 phasig 220 240D ...

Page 14: ...eten Behälter ausreichender Größe aufzufangen 6 Fördermedien Das Fördermedium darf die Pumpenwerkstoffe chemisch nicht angreifen pH Wert 4 10 Die POMONA Pumpen sind unempfindlich gegenüber Verunreini gungen durch Schlamm Schmutz oder Sand Die Pumpe ist nicht zur kontinuierlichen Förderung Achtung von Medien mit abrasiven Bestandteilen wie z B Schwemmsand geeignet Ohne dass die Gefahr des Verstopfe...

Page 15: ...m Betonfundament zu montieren das groß genug ist um eine dauerhafte und sichere Abstützung der gesamten Pumpe zu gewährleisten Weiterhin muss das Fundament Schwingungen und die im ord nungsgemäßen Betrieb auftretenden Kräfte oder Stöße aufneh men können Als Richtwert sollte das Gewicht des Fundaments das 1 5 fache des Pumpengewichts betragen Die Oberfläche des Betonfundaments muss absolut waagerec...

Page 16: ...kels oder vor dem Zerlegen der Pumpe muss die Pumpe voll ständig von der Spannungsversorgung getrennt wer den Der elektrische Anschluss ist von einer Elektrofachkraft in Über einstimmung mit den Vorschriften des Energieversorgungsunter nehmens und des VDE vorzunehmen Die Pumpe ist bauseits über die Elektroinstallation des Gebäudes abzusichern und an einen externen Schalter anzuschließen Es ist dar...

Page 17: ...e Weise wird ein Ein dringen der Förderflüssigkeit in das Erdreich verhindert Es ist zu beachten dass auch der Motor den Sicherheitsanforde rungen genügt Die Wartung an einem Benzin oder Dieselmotor ist entsprechend den Vorgaben des Herstellers durchzuführen 11 2 Gleitringdichtung Gleitringdichtungen sind wartungsfrei und arbeiten praktisch ohne Leckverluste Bei stärkerer oder zunehmender Leckage ...

Page 18: ...e Pumpe spannungsfrei in die Rohrleitungen ein bauen Rohrleitungen haltern Falls eine kleinere Förderleistung als angegeben aus reicht die Fördermenge an der Saugseite eindrosseln Ansonsten einen größeren Motor wählen d Motorschutzschalter falsch eingestellt Die Einstellung überprüfen und ggf anpassen Ggf den Motorschutzschalter austauschen e Trotz Drehstrom läuft der Motor nur auf zwei Phasen Den...

Page 19: ...u groß Saugseitigen Flüssigkeitsstand erhöhen Das Absperrventil in der Saugleitung öffnen c Die Lager sind unzureichend mit zu viel Fett d Das Pumpengehäuse mit dem Lagerträger steht unter Spannung e Motorschutzschalter defekt oder falsch ein gestellt Bitte wenden Sie sich an den Hersteller Die Pumpe spannungsfrei einbauen Die Rohrleitungen an geeigneten Punkten haltern Die Ausrichtung der Kupplun...

Page 20: ...chstgelegene Kundendienststelle des Motorlieferanten zu schi cken Die Anschriften können der der Pumpe beigefügten Betriebsan leitung des Motorlieferanten entnommen werden 15 Entsorgung Dieses Produkt sowie Teile davon müssen umweltgerecht ent sorgt werden 1 Nutzen Sie die öffentlichen oder privaten Entsorgungs gesellschaften 2 Ist das nicht möglich wenden Sie sich bitte an die nächste Steffens Ge...

Page 21: ...32 PLQ 62 136 136 P 3 4 PñK WD N WD 3 4 Pñ K 4 OV Fig 1 Performance curves for 1 and 3 phase motors POMONA 23 S N3D P 4 4 PLQ PLQ 32021 32 PLQ PLQ 62 136 P 136 3 N 4 Pñ K WD 3 WD 3 WD 4 Pñ K 4 O V Fig 2 Performance curves for 1 and 3 phase motors and 4 stroke petrol engine ...

Page 22: ...021 32 PLQ 62 136 P 136 3 N 4 Pñ K WD WD 3 4 Pñ K 4 OV Fig 3 Performance curves for 3 phase motors and diesel engine POMONA 42 S N3D P 4 32021 32 PLQ 62 136 P 136 3 N 4 Pñ K WD WD 3 4 Pñ K 4 O V Fig 4 Performance curves for 3 phase motors and diesel engine 97 ...

Page 23: ...der Rechtsvorschriften der EG Mitgliedsstaaten übereinstimmen Maschinenrichtlinie 2006 42 EG Verwendete Normen EN809 1998 Niederspannungsrichtlinie 2006 95 EG Elektromagnetische Verträglichkeit 2004 108 EG Elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen 2006 95 EG Verwendete Normen EN60034 1 Delbrück den 22 11 2016 Andreas Steffens Geschäftsführer Steffens Pumpen Fa...

Page 24: ...the approximation of the laws of the member states of the European community Machinery directive 2006 42 EG Standards used EN809 1998 Low voltage directive 2006 95 EG Electromagnetic compatibility 2004 95 EG Electrical equipment for use within certain voltage limits 2006 95 EG Standards used EN60034 1 Delbrueck 22 November 2016 Andreas Steffens Managing Director Steffens Pumpen Fachhandel GmbH ...

Reviews: