6
Fig 6
6.1. Terminal
⑥
and
⑦
it for connecting to 220V power
6.2. Connect to sliding gate motor
6.2.1.Install the motor on the right of gate.(Please see Fig 7)
Fig 7
When the motor being installed to the right of gate , motor wires diagram follows
Terminal
③
connect the red wire from motor. and
Terminal
④
connect the yellow wire from motor.
Terminal
⑤
connect the blue wire from motor.
6.2.2. Install the motor on the left of gate.
(Please see Fig 8)
Please note: Our factory setting is install motor on the right of gate!