Program selection Name
Option Meaning
18
Power-on
duration for load
output
480
Can be set from 0 min to 480 min
in increments of 5 min
(default setting: 480 min)
Can only be set if "LIG" is set in
program 16
19
PV voltage to
define sunrise
and sunset time
15.0
12 V rated voltage:
Can be set from 10 V to 80 V in
increments of 1 V
(default setting: 15.0 V)
30.0
24 V rated voltage:
Can be set from 20 V to 80 V in
increments of 1 V
(default setting: 30.0 V)
60.0
48 V rated voltage:
Can be set from 40 V to 80 V in
increments of 0.1 V
(default setting: 60.0 V)
20
Temperature
compensation for
battery voltage
4
Can be set from 0 mV to 10 mV
in increments of 1 mV
(default setting: 4 mV)
21
Performance
compensation for
battery voltage
0
Can be set from 0 mV to 30 mV
in increments of 1 mV
(default setting: 0 mV)
The cables between solar charge
controller and battery cause
losses. This value compensates
the losses by shifting the voltage.
If, for example, 10 mV are
specified, the charging end
voltage is increased by 10 mV
per ampere of charging current.
At the same time, this value is
deducted per ampere from the
under-voltage cutoff
(program 14)