background image

 

1  Safety instructions and liability exclusion 

1.1  Identification of safety instructions 

In this manual safety instructions for personal security are identified by this symbol 

and are in bold type. 

Information concerning the operational security of the equipment is in bold type. 

The manufacturer’s safety instructions for additional components you may connect to this charging station must be 
observed and are not cancelled by these instructions.  In the event of any contradictions between different sets of 
instructions please contact the specialist supplier. 

1.2  About this manual 

This manual describes the operation and installation of a charging station for photovoltaic solar units intended for feeding 
solar electricity into lead storage batteries 

The relevant manufacturer’s installation instructions must be observed for installing the solar cells and setting up the 
batteries.  

Tip: 

Before starting work please read the section entitled Installation (Chapter 3; page 7).  Ensure that all preparatory 
measures have been taken before installation. 

Do not start installing the equipment until you are certain that you have understood the technical instructions and only 
carry out the work in the order specified in this manual! 

The manual must be available, to third parties as well, during all work that is carried out on the system. 

This manual is an integral part of the charging station and must be handed over when the station is disposed of. 

1.3  General safety instructions 

For your safety it is imperative that you observe the following instructions during installation:  

Avoid sparking during all work!  

Photovoltaic modules generate electricity when they admit light.  The voltage is at its full level even with a low incidence 
of light, so exercise care when working and take appropriate safety precautions. 

Voltages as high as double the system voltages, that is up to 48V, can occur during assembly and electrical installation in 
the photovoltaic system’s direct current circuit. 

Therefore: never touch bare lead ends! 

 

Only use properly insulated tools! 

Do not use any measuring equipment you know to be damaged or defective! 

The safety control inherent in the design of the charging station can deteriorate if it is operated in a manner not specified 
by the manufacturer. 

Obstruction of the equipment ventilation can lead to overheating and thence to breakdown of the equipment.  Do not 
cover ventilation openings and heat dissipators. 

The charging station is only suitable for indoor use, where it is protected from the effects of the weather such as rain and 
direct sunlight. It must not be installed and operated in damp areas (e.g. bathrooms), or in rooms in which easily 
combustible gas mixtures can occur, such as from gas bottles, paints, varnishes, solvents, etc! 

Do not store any of the above-named materials in rooms where the charging station is installed! 

The notices and markings placed on the equipment at the factory must not be altered, removed or rendered 
indecipherable. 

All work must be carried out in accordance with the national electrical requirements and the appropriate local regulations! 

Where the equipment is installed abroad information must be obtained from the relevant institutions or authorities 
concerning regulations and safety control. 

Keep children away from the control electronics and the battery area! 

 

 

 

Operating instructions PL2085 charging station 

Page 3 

10.12.2007 

Summary of Contents for PL2085

Page 1: ...User s and Installer s Manual Charging Station for Photovoltaic Systems PL2085 704 937 07 50 PHOTOVOLTAIK PHOTOVOLTAIC PHOTOVOLTAIQUE FOTOVOLTAICA EN...

Page 2: ...5 Charging in order of priority 6 2 2 6 Ampere hour meter 6 2 2 7 Rotary switch 6 2 2 8 Display 7 2 2 9 System voltage 7 3 Installation 7 3 1 Precautionary measures 7 3 2 Choice of location for instal...

Page 3: ...g all work Photovoltaic modules generate electricity when they admit light The voltage is at its full level even with a low incidence of light so exercise care when working and take appropriate safety...

Page 4: ...ng station The batteries are charged as quickly as possible and also economically in order of priority according to when they were connected and using the latest charging process In addition an MPP Tr...

Page 5: ...gh energy is available and this battery is next in line as far as priority is concerned the charging station starts charging an intact empty battery once it has been connected with up to 5A first thir...

Page 6: ...on to about 35mA In this mode the charging station draws its supply from a battery connected to it This is necessary in order that important data such as the priorities and charging phases of the batt...

Page 7: ...odation National Electric Code with Article 690 3 2 Choice of location for installation Ideally the charging station should be installed in the same well ventilated room as the batteries minimum clear...

Page 8: ...arking will occur Only use properly insulated tools Never touch bare lead ends Insulate immediately every bare lead end that is not going to be connected straight away Only carry out installation work...

Page 9: ...the batteries Then the modules must be separated from the control unit In order to avoid sparking this must be carried out at night or with the modules covered 3 4 Safety measures 3 4 1 Flammability...

Page 10: ...ging station is charging the batteries but that no battery was selected for further information 4 1 2 Description of second line of display The charging and error states of the 8 channels are indicate...

Page 11: ...ary switch is not set to CHARGE STOP The battery that was connected first has priority and is charged first If the display shows a full unchanging battery symbol this means that this battery has finis...

Page 12: ...ted against destruction by a variety of measures Nevertheless great care should be taken to ensure that the charging station is operated correctly Some of the malfunctions are signalled by the display...

Page 13: ...f notification of the fault is provided immediately after it is discovered Legal guarantee claims are to be directed to the seller The seller must be informed before legal guarantee claims are process...

Page 14: ...704937...