I N S T A L L A T I O N
Installation – step 5
Power supply installation
Electrical Warning
Risk of electric shock
.
Any work related to power supply installation of this humidifier must comply with local code
and regulation regarding safety and prevention of accidents.
steamOres electrical rating
Model
Voltage
Steam
Capacity
Power
Current
Power supply connection
RES120-06
120Vac/1ph
1.9lb/h
(0.86kg/h)
0.6kW
5.2A
Supplied with power cord &
standard plug
RES120-08
2.4lb/h
(1.09kg/h)
0.8kW
6.7A
RES120-11
3.4lb/h
(1.5kg/h)
1.1kW
9.4A
RES120-15
4.5lb/h
(2.0kg/h)
1.5kW
12.5A
RES208-19
208Vac/1ph
5.6lb/h
(2.5kg/h)
1.9kW
9.1A
To be wired by Qualified
electrician
RES208-24
7.2lb/h
(3.3kg/h)
2.4kW
11.6A
RES208-34
10.1lb/h
(4.6kg/h)
3.4kW
16.3A
RES208-45
13.5lb/h
(6.1kg/h)
4.5kW
21.7A
RES240-25
240Vac/1ph
7.5lb/h
(3.4kg/h)
2.5kW
10.4A
RES240-32
9.6lb/h
(4.4kg/h)
3.2kW
13.3A
RES240-45
13.5lb/h
(6.1kg/h)
4.5kW
18.8A