background image

4V130P-430P SERIES AIR PILOT VALVE

 

 

 

Valve Model 

4V130P-1/8 

4V230P-1/4 

4V330P-3/8 

4V430P-1/2 

Port & Mounting 

Body Ported 

Action & Motion 

Double Solenoid, Spool Design, 3 Position, Pressure Center, Response Time <20ms 

Operating Pressure 

21 to 115 PSI 

Port Sizes 

1/8 NPT 

1/4 (in/outlet) 
1/8 (exhaust) 

3/8 (in/outlet) 
1/4 (exhaust) 

1/2 NPT 

Operating Temp. 

14 to 140 °F 

C

v

 

0.67 

0.89 

1.68 

2.79 

SFCM @ 100PSI 

25 

53 

80 

160 

Manual Override 

Detentable 

Electrical Connection 

Grommet, DIN 

Working Medium 

40 micron filtered air or inert gas 

Coil Insulation & 

Protection Class 

IP 65, Class F 

Coil Duty Cycle 

100% ED 

Coil Voltage Options 

Options: 12, 24 VDC;  24,110/120, 220/240 VAC (50/60Hz) 

Coil Power 

2.5W 

3/4.8W 

Valve Body Material 

Anodized Aluminum 

Seal Material 

NBR (Buna N) 

Lubrication 

Not Required 

Summary of Contents for 4V130P-430P Series

Page 1: ...haust 3 8 in outlet 1 4 exhaust 1 2 NPT Operating Temp 14 to 140 F Cv 0 67 0 89 1 68 2 79 SFCM 100PSI 25 53 80 160 Manual Override Detentable Electrical Connection Grommet DIN Working Medium 40 micron filtered air or inert gas Coil Insulation Protection Class IP 65 Class F Coil Duty Cycle 100 ED Coil Voltage Options Options 12 24 VDC 24 110 120 220 240 VAC 50 60Hz Coil Power 2 5W 3 4 8W Valve Body...

Page 2: ...4V130E 430E SERIES SOLENOID VALVE DIMENSIONS 2 ...

Page 3: ...4V130E 430E SERIES SOLENOID VALVE DIMENSIONS 3 ...

Page 4: ...perational Notes Continuous power to the coil is not required to maintain the solenoid position To move the piston to a new position power the corresponding coil Do not power both coils at the same time Turn off power to the coil when piston reaches desired position Installing Valve onto Manifold Note Manifolds can fit 2 4 6 8 and 16 valves Secure screws until the component will not move freely an...

Page 5: ...nect Positive to RED wire and Negative to Black wire 2 If the DC solenoid has two same color wires connect Positive to one of the two wires and Negative to the other wire AC Coil 1 If the AC solenoid coil has a black a white wire Connect the HOT wire to BLACK wire and Neutral to WHITE wire 2 If the AC solenoid has two same color wires connect HOT wire to one of the two wires and NEUTRAL wire to th...

Page 6: ...rations 1 When Valve is in Position 1 Port P is connected to Port A Port B is connected to Port EB 2 When Valve is in Position 2 Port P is connected to Port A and B Port EA and EB are Closed The Valve is spring centered 3 When Valve is in Position 3 Port P is connected to Port B Port A is connected to Port EA A EB P A B B EA EB EA P 3 A EB P B EA 6 ...

Page 7: ...of the original purchase price of this product at STC s option Purchaser has thirty 30 days to return the goods after STC has agreed to accept the return All freight charges on returned material shall be paid by the Purchaser STC s limited warranty shall not apply however to the product that have been subjected to misuse alteration accident or negligence during handling or storage DISCLAIMER OF IM...

Reviews: