PROsine 2.5/3.0 Advanced Control System (ACS) Owner’s Manual

 11

3. Installation

The ACS Panel should be installed in a location that is most convenient for you
so the important display and control information is easily accessible.

To connect the Control Panel

1.

 

Decide on the location of choice for the ACS Panel. For flush mount
installation onto a wall, the remote panel requires an opening with the
measurements of 4 1/8 inches by 4 1/8 inches (10.5cm by 10.5cm).  Ensure
there is no wiring or other obstruction within the wall before making this
opening as the ACS Panel requires approximately 2 inches (5cm) of free
space within the wall to accommodate its depth.

2.

 

Connect the supplied cable to the ACS panel and route the cable back through
the wall opening and back to the PROsine unit. Keep the EMI bead (large
yellow bulb on cable) close to the PROsine unit and don’t plug the cable in
with the EMI bead closer to the ACS Panel (it is far more effective close to
the base chassis).  Connect the cable to the REMOTE output connector jack
found on the side of the PROsine itself (the panel can be connected to either
output).

3.

 

If you purchased the ACS Panel as an accessory to be used with your
PROsine 2.5, the ACS Panel and standard supplied panel can both be used at
the same time.  Either connect the standard panel to the OUTPUT jack on the
back of the ACS Panel, or connect the standard panel to the REMOTE output
connector jack on the side of the PROsine Inverter•Charger. The standard
panel can then be mounted close by the PROsine unit for system monitoring
in that location and the ACS Panel can be mounted remotely in some other
area where you want the more detailed operating information and control
capability.

Summary of Contents for Prosine 2.5

Page 1: ...ighway Burnaby BC Burnaby BC Burnaby BC Burnaby BC V5A 4V8 Canada V5A 4V8 Canada V5A 4V8 Canada V5A 4V8 Canada Tel 604 420 1585 Tel 604 420 1585 Tel 604 420 1585 Tel 604 420 1585 Fax 604 420 1591 Fax...

Page 2: ......

Page 3: ...7 2 2 2 BATTERY INFO 8 2 2 3 INVERTER 8 2 2 4 CHARGER 9 2 2 5 SYSTEM INFO 9 2 2 6 STATPOWER INFO 10 2 3 CONFIGURING INSTALLER SETTABLE PARAMETERS 10 3 INSTALLATION 11 4 TROUBLESHOOTING 12 5 WARRANTY 1...

Page 4: ...of the ACS gives you a detailed display of many parameters for the system while the menu structure allows advanced configuration as well as the convenience to change system settings when you need to C...

Page 5: ...in the following instructions For some menus if you hold the button down it will scroll rapidly through the numerical values 1 Moves down one option in the selected menu or 2 Selects the next lower va...

Page 6: ...ANDBY and INVERT LEDs are off Incoming AC power will still be passed through to the load terminals CHARGER ON OFF 1 Press the ON OFF button to switch the PROsine charger to standby mode if no AC power...

Page 7: ...round the PROsine INVERTER INVERT ON when the PROsine is operating in inverter mode FLASHING when the PROsine inverter is in Search mode AC output power is available from the PROsine Inverter is waiti...

Page 8: ...as been enabled Flashing CHARGE and EQUALIZE LEDs indicates PROsine charger is equalizing the batteries Equalize over voltage charging is used to break down sulfation of the battery plates and should...

Page 9: ...rom the battery while the indicates charger mode operation positive current direction to the battery 2 1 Menu Selection To navigate the menu and select parameters follow these instructions 1 Press the...

Page 10: ...90A SELECT FROM AC INFORMATION SELECT FROM BATTERY SELECT FROM INVERTER SELECT FROM CHARGER SELECT FROM SYSTEM INFO SELECT FROM STATPOWER INFO SELECT FROM AC INFORMATION AC INFORMATION OUTPUT 120 Vac...

Page 11: ...0 Ah USER SETTABLE adjustable from COLD ambient 10C 50F WARM 10C 50F to 27C 80F and HOT 27C 80F Set to best match ambient conditions giving batteries a temperature compensated charge If battery temper...

Page 12: ...O DEFAULT INV CHG SYSTEM INFO ALARM AUDIBLE SYSTEM INFO LAST FAULT 0 USER SETTABLE between 4 initial power up combinationsof inverterand chargerON OFF USER SETTABLE between audible alarm ENABLED and D...

Page 13: ...batteries or could severely affect the performance of your system You will not be able to change parameters that are installer settable unless you enter the ACS Panel into installer mode To enter inst...

Page 14: ...and back to the PROsine unit Keep the EMI bead large yellow bulb on cable close to the PROsine unit and don t plug the cable in with the EMI bead closer to the ACS Panel it is far more effective close...

Page 15: ...ther try a Battery Heating Blanket 2 Replace the faulty battery 3 Check connections replace probe 002 Battery Voltage is too low 1 Discharged battery 2 Old or faulty battery 3 Battery cables to the PR...

Page 16: ...contact Statpower 129 136 192 196 Internal fault Various Record the error code and contact Statpower 197 Unexpected AC output voltage AC Input Line Neutral is reversed Check AC Input wiring There sho...

Page 17: ...gger a fault condition 2 There is an internal hardware or software fault 1 Contact Statpower if you find incompatibility with certain type of loads 2 Record the error code and contact Statpower 207 In...

Page 18: ...in an unsuitable environment This warranty will be considered void where the product has been misused neglected improperly installed or repaired or modified by anyone other than Statpower without prio...

Page 19: ...rocedure 1 Obtain a Return Authorization Number from Statpower You will be required to provide name telephone number return shipping address and a Federal ID or Social Security number required by US C...

Reviews: