Appendices
68
Instruction Manual SCE
A
is
A.2
Electrical diagram SCE
A.2.1
Electrical diagram SCE 65-500 LP
TERMINAL BLOCK CONNECTIONS:
A
Earth
N
Neutral
L
Phase
L
1
Phase input on control program
L
2
Phase input on thermal non-return safety device
L
3
Phase input from safety circuit for temperature control release
NO Normal open
P
Supply PVC
NC Normal closed
COMPONENTS:
A
Burner controller Two-terminal main switch
- N Neutral
-
A
Earth
- L'
Phase input on control program
- L" Phase output
- TH Thermostats circuit phase input
- GV1 Phase output to gas control
- MAXSafety thermostat phase input
- LG Phase output to glow igniter
- I
Ionisation detection = output
- NO Normal open
- P
Phase input alarm
- NC Normal closed
- F1 Fuse (T5A)
- R1 Relay max 250V-10A
B
Frost thermostat
C
Control thermostat
D
I/0/II-switch
E
Safety thermostat
F
Maximum thermostat
G
Gas control
H
Glow igniter
J
Ionisation pin
K
High-low regulator
L
Timer
M
Storing indicator
N
In operation indicator
O
Reset button
OPTIONAL COMPONENTS:
P
Main control switch
Q
Potentiostat (for power anodes)
R
Thermal non-return safety device
S
Week timer switching
Figure A.1
Electrical diagram SCE 65-500 LP
brown
blue
yellow/green
black
Summary of Contents for SCE 65-400
Page 2: ...your installer ...
Page 4: ...4 SCE Instruction Manual ...
Page 8: ...8 Instruction Manual SCE gis ...
Page 12: ...Introduction 12 Instruction Manual SCE 1 gis ...
Page 18: ...Operating the appliance 18 Instruction Manual SCE 2 gis ...
Page 42: ...Installation 42 Instruction Manual SCE 3 is ...
Page 46: ...Filling and draining 46 Instruction Manual SCE 4 gis ...
Page 64: ...Maintenance 64 Instruction Manual SCE 9 s ...