CCD camera user manual

General description:

The SX-46 is the first in a new range of ‘Full Frame’ CCD cameras from Starlight Xpress. This camera
is based on the ON Semiconductors KAF 16200 CCD, which has 16.5 million 6uM square pixels in a
4540 x 3640 APS-H format. Full Frame sensors require a mechanical shutter to obstruct light during
readout, so an important component of this camera is a unique ‘roller blind’ shutter, which is stepper
motor driven and provides perfectly uniform exposures across the entire CCD surface. Other important
design features include high performance 3 stage cooling, a CCD ‘flood’ facility to eliminate RBI im-

Summary of Contents for Trius SX-46

Page 1: ...AF 16200 CCD which has 16 5 million 6uM square pixels in a 4540 x 3640 APS H format Full Frame sensors require a mechanical shutter to obstruct light during readout so an important component of this c...

Page 2: ...4Gb of memory If you intend to view the fin ished images on its screen then you will also need a graphics card capable of displaying an image in a minimum of 1920 x 1080 pixels and 32 bit colour A med...

Page 3: ...ss from popular third party software such as Sequence Generator Pro It will also work with MaximDL AstroArt Nebulos ity etc Testing the camera Plug the USB cable into the camera and then connect the 1...

Page 4: ...ng a piece of aluminium foil to the input adaptor and punching a tiny hole in the centre using a pin or needle If the camera is on a tele scope you can try using ND filters or cutting a small hole in...

Page 5: ...Handbook for the SX 46 Full Frame camera Issue 2 22nd March 2018 The exposure control menu A short exposure of M42 The histogram sliders have been set to show faint image detail...

Page 6: ...ave the option of Auto saving image sequences This is set up by pressing the Auto Actions button and then setting up the desired sequence length and file name directory details Once selected close the...

Page 7: ...pattern but this is now uniform and no longer shows as a recognisable image The flood technique does increase the background noise to some degree and so it should not be used for every image just app...

Page 8: ...B cables to interface with the port sockets on the rear of the cam era A set of suitable cables is supplied with the SX 46 and spares are available from SX Ltd The hub is capable of supplying up to ab...

Page 9: ...Handbook for the SX 46 Full Frame camera Issue 2 22nd March 2018 Maintenance and servicing information...

Page 10: ...en by using the Test facility in the SX Vision software The window can then be blown clean with an air cannon and the camera quickly returned to operation In more difficult cases you may want to open...

Page 11: ...motors Do not worry if this happens just rotate the motor shafts to align with the flats in the shutter drums and slide them back on The sapphire chamber window is now easily accessible for cleaning A...

Page 12: ...window retaining plate Be careful that the window does not fall out when the retaining plate is removed 3 Hold a soft cloth in front of the camera and tip the camera body forwards The sapphire window...

Page 13: ...argon chamber you will need a simple adaptor to fit into the argon input port hole The hole is an M4 threaded bore and so the adaptor should be about 3 3 mm in outside diameter and about 5mm long Thi...

Page 14: ...urn off the flow and re fit the exhaust port sealing screw Now pull the adaptor out of the in put port and quickly re fit the input port sealing screw SX 46 specifications CCD specs Active area 27 x 2...

Page 15: ...EE 1 The equipment shall only be used for normal purposes described in the standard operating instructions and within the re levant safety standards of the country where the equipment is used 2 Repair...