97
Section 7: Fuel & Propane System
6.
Attach the 1/4” inverted flare x 24” Type 1 pigtail hose to the regulator inlet and the
right hand swivel nut to the cylinder valve.
7.
Secure the cylinder to the A-frame bracket using the bolts, nuts and washers provided.
Double Cylinder Mounted On A-Frame (if so equipped)
When a second cylinder is installed, a tee check valve is
used to replace the 90° elbow at the top of the regulator
and another 1/4” inverted flare x 24” Type 1 pigtail is
added. The regulator stays in the original position.
Place the second cylinder on the A-frame bracket so the
cylinder valve is pointed to the roadside of the recre-
ation vehicle.
1.
Secure the second cylinder to the A-frame using
the bolts, nuts and washers provided.
2.
Attach the second 24” hose to the tee check valve
on the regulator and the right handed swivel nut to
the cylinder valve.
Located in a recessed compartment or housing (if so equipped)
1.
Connect the 3/8” low-pressure hose to the outlet of the
two-stage regulator.
2.
Place the cylinder on the bracket in the recess compart-
ment or housing and secure them so the outlets of the
cylinder valves are facing the “sidewalls” of the com-
partment or housing (opposite of each other).
3.
Mount the regulator on the center back wall of the com-
partment or housing so the vent is pointed downward.
4.
Attach the 1/4” inverted flare x 18” Type-1 pigtail hose
to the regulator inlet and the right hand swivel nut to
the cylinder valve.
Main Supply Hose – Low Pressure
Attach the main supply hose from the regula-
tor to the brass manifold fitting in the frame
of the trailer. The swivel brass nut on the
main hose will be your final attachment.
Each time the propane container is removed:
1.
Check that ALL fittings are tight.
2.
Check that ALL connections are tested with a propane leak detector (or soapy water)
solution.
3.
Open the main valve slowly to avoid a fast rush of propane to the excess flow valve
causing propane freeze up. If you experience a propane “freeze-up,” close the main
valve and wait at least fifteen (15) minutes before trying again. Refer to the regulator
manufacturer’s operator manual.
4.
Listen carefully - a “hissing” sound longer than one second may indicate a propane
leak. If you feel there may be a leak present, close the valve and contact your dealer or
qualified propane technician for repair assistance.
Replace all protective covers and caps on the propane system after filling. Make sure the
valve is closed and the compartment door is securely latched.
Double Cylinder
Two Propane Cylinders
Main Supply Hose
Maintenance Record
Table of Contents
Summary of Contents for SUPER LITE 2021
Page 1: ...2021 Owner s Manual 0335747 2021 Asubsidiary of Thor Industries Inc Travel Trailers...
Page 2: ......
Page 32: ...30 Section 2 Occupant Safety Table of Contents Maintenance Record...
Page 42: ...40 Section 3 Pre Travel Information Notes Table of Contents Maintenance Record...
Page 90: ...88 Section 6 Electrical System Notes Table of Contents Maintenance Record...
Page 100: ...98 Section 7 Fuel Propane System Notes Table of Contents Maintenance Record...
Page 126: ...124 Section 8 Plumbing System Notes Table of Contents Maintenance Record...
Page 138: ...136 Section 10 Appliances Notes Table of Contents Maintenance Record...
Page 140: ...138 Section 11 Electronics Notes Table of Contents Maintenance Record...
Page 153: ...151 Section 13 Exterior Travel Trailers Sealant Diagram Maintenance Record Table of Contents...
Page 154: ...152 Section 13 Exterior Notes Table of Contents Maintenance Record...
Page 158: ...156 Section 14 Travel Camping Storage Checklists Notes Table of Contents Maintenance Record...