-18-
ARROW STICK OPTION JUMPERS
The TDC850 controller that is shipped with the LCS881 has been designed so that it
can operate three different styles of traffic directors:
•
Independently Switched Heads:
Each Head is independently controlled by a
ground-side switched wire.
•
3-Wire Logic Controlled Heads:
Left, Right, and Warn functions are controlled
by delivering power to 3 separate wires.
Center-Out function activated by delivering
power to both Left and Right functions
(wires) at the same time.
•
4-Wire Logic Controlled Heads:
Specifically designed for the DL15-30W.
Power wire activates Warn function. Right,
Left, and Center-Out functions controlled by
delivering low current to 3 separate wires (in
addition to Power wire).
Please review the instructions that came with your traffic director and then
reference the corresponding section(s) in this manual for the type of traffic director
that you will be installing.
Arrow stick Control Box Cover Removal
1. Remove the four recessed Philip head screws (two
on each side of the arrow stick control box).
2. Remove the top cover by sliding it towards the
front of the unit.
Included with the LCS881 is the TDC850 arrow stick controller. There are several
jumpers located inside the TDC850 that control different options for traffic directors.
Review the following section to determine if you need to open the case and
change any of the jumper options inside the TDC850.
Arrow Stick Settings and Connections
(LCS881 only)
Extra Jumper
Locations
4-Wire
Logic Mode
3-Wire
Logic Mode
TDC850 Controller
Standard
Mode
Option Header
Location
Arrow Stick Control Mode Setting
The Standard Mode is designed to control traffic directors with independently
switched heads. If you have a 3- or 4-wire controlled arrow stick (as described
above), check the Option Header Location and configure the jumpers as pictured
below.