background image

GAS 

 HOT PLATES

MODEL

601SPRD 

602HDS, 602HWD, 602HD, 602HD-SU 

604HD, 604HD-SU
606HD, 606HD-SU

Installation and 

Operation 

Instructions

2M-Z6103 Rev. D  7/23/10 

606HD-SU

Summary of Contents for 602HD

Page 1: ...GAS HOT PLATES MODEL 601SPRD 602HDS 602HWD 602HD 602HD SU 604HD 604HD SU 606HD 606HD SU Installation and Operation Instructions 2M Z6103 Rev D 7 23 10 606HD SU...

Page 2: ...omissions in information provided or conclusions reached as a result of using the specifications By using the information provided the user assumes all risks in connection with such use MAINTENANCE A...

Page 3: ...appliance and its pressure regulator must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at te...

Page 4: ...supply line CHECKING FOR GAS LEAKS Soap and water solution or other material acceptable for the purpose shall be used in locating gas leakage Matches candle flame or other sources of ignition shall no...

Page 5: ...t require a conversion these can be converted to natural gas using the natural gas orifices and converting the regulator to natural gas 1 Set regulator outlet pressure to 10 water column A 1 8 pipe pl...

Page 6: ...rs This warranty does not apply to the non stick properties of such materials This warranty does not apply to Special Products but to regular catalog items only Star s warranty on Special Products is...

Page 7: ...1 2 3 24 4 5 7 9 10 12 13 14 16 17 18 19 20 21 8 9 8 22 6 15 NAMEPLATE 11 GAS HOTPLATE MODEL 602 604 606 STAR MANUFACTURING INTERNATIONAL INC SK1527 REV D 6 17 10...

Page 8: ...1 2 3 4 5 7 9 10 12 13 14 16 17 18 19 20 21 8 9 8 22 6 15 24 NAMEPLATE 23 11 STAR MANUFACTURING INTERNATIONAL INC SK1528 REV D 6 16 10 GAS HOTPLATE STEP UP DESIGN MODEL 602HD SU 604HD SU 606HD SU...

Page 9: ...606HD 10 2F Z0747 2 4 6 VENTURI ALL 602 604 606HD 11 2I Z0752 2 4 6 GASKET ALL 602 604 606HD 12 2F Z0637 2 4 6 GRATE ALL 602 604 606HD 13 2F Z0615 2 4 6 BURNER ALL 602 604 606HD 14 I4 HP0023 1 BODY A...

Page 10: ...10 1 2 3 4 5 7 9 10 12 13 14 16 17 18 19 21 8 11 6 15 20 NAMEPLATE STAR MANUFACTURING INTERNATIONAL INC SK1529 REV B 10 3 02 GAS HOTPLATE MODEL 601SPRD...

Page 11: ...ot Adjustment 4 2V Y8832 2 VALVE MANUAL 5 2J Z1157 2 ORIFICE 125 NATURAL GAS 6 I4 Z1169 2 ORIFICE 45 PROPANE 7 I4 Z6203 1 SHIELD FRONT 8 I4 601003 2 PILOT TUBE ASSEMBLY 9 2F Z0816 2 AIR SHUTTER 10 2F...

Page 12: ...r le propane peints en noir no 54 pour tous les mod les l exception du Mod l 601SPRD qui utilise les orifices no 45 situ s dans l tui plac l ext rieur du panneau avant Pour retirer les orifices pour l...

Page 13: ...cun des br leurs Mod l 601SPRD 45 000 BTU H pour chacun des br leurs La pression de sortie du r gulateur est 254 mm de colonne d eau 10 pouces Remarque L appareil est quip de couvercles d orifices pou...

Page 14: ...soit parfaitement align e et de niveau avec les autres unit s s ries Star Max MISE EN GARDE NE PAS RETIRER LES PIEDS CANALISATIONS DE GAZ Les canalisations de gaz devraient tre neuves propres de tail...

Page 15: ...apide SYMBOLE DE S RET 2 DONN ES G N RALES D INSTALLATION MISE EN GARDE Cet quipement est con u et vendu pour une utilisation commerciale seulement et pour tre utilis par un personnel form et exp rime...

Page 16: ...16 PLAQUES CHAUFFANTES AU GAS MOD LES 601SPRD 602HDS 602HWD 602HD 602HD SU 604HD 604HD SU 606HD 606HD SU Instructions d installation et d op ration 2M Z6103 Rev D 7 23 10 606HD SU...

Reviews: