ECO FRESH AIR
AIR COOLER
INSTRUCTION MANUAL
NEW WITH UV DEVICE FOR WATER STERILIZATION
IPX4
FOR OUTDOOR USE
1
Page 1: ...ECO FRESH AIR AIR COOLER INSTRUCTION MANUAL NEW WITH UV DEVICE FOR WATER STERILIZATION IPX4 FOR OUTDOOR USE 1 ...
Page 2: ...ve air cooling is the natural way of cooling similar to a breeze blowing across a fountain This breeze drops the temperature and has a relaxing cooling effect The evaporative air cooler cools the air by means of the evaporation of water When water evaporates into the air the result is a mixture of air and water molecules This chemical change requires heat which is taken from the water molecules re...
Page 3: ...the cable or the power plug are damaged take the appliance to manufacturer or to an authorised service centre for replacement or a professionally qualified electrician IMPORTANT WARNINGS THE APPLIANCE MUST BE PLACED PERFECTLY IN PLAN WE RECOMMEND THE USE OF CLEAN WATER IF YOU ARE USING WATER NOT FROM THE WATER NETWORK APPLY A FILTER TO MOUNT THE WATER LOAD IF THE APPLIANCE IS USED IN ENVIRONMENTS ...
Page 4: ...vegetable markets gymnasiums underground parking lots greenhouses chicken and pig farms gardens the list goes on TECHNICAL FEATURE TECHNICAL SPECIFICATION MODEL MODEL MODEL MODEL CODE CODE CODE CODE KT KT KT KT 1E 1E 1E 1E 3 3 3 3 FRE8000 FRE8000 FRE8000 FRE8000 Max Airflow m3 h 8000 Power supply Vac Frequency HZ 220 240 50 Power Consumption W 430 Fan Style Axial Water Consumption L h 6 8 Water Ca...
Page 5: ... Effective Cooling Area m2 250 MODEL MODEL MODEL MODEL CODE CODE CODE CODE KT KT KT KT 1B FRE 1B FRE 1B FRE 1B FRE18000 18000 18000 18000 Max Airflow m3 h 18000 Power supply Frequency V HZ 220 240 50 Power Consumption W 700 Fan Style Axial Water Consumption L H 10 15 Water Capacity L 60 Dimension L W H mm 1120 x 720 x 1500mm Weight kg 65 Effective Cooling Area m2 300 350 MODEL MODEL MODEL MODEL CO...
Page 6: ...Delayed start The timer setting can be used to start the cooler after a certain number of hours delay When only the green POWER light is on press TIMER until the number of hours delay 1 24 is shown TIMER Automatic stop When the cooler is already going press timer to set the number of hours 1 24 until the machine will automatically switch off WATER SUPPLY Use only clean fresh water Pour water into ...
Page 7: ...er Pushing too hard will cause the cooler to overbalance and tip over which may cause injury and will damage the cooler MAINTENANCE For best results and long term operation regular maintenance is essential To ensure the cooler delivers fresh and clean air regularly change the water when dirty and clean both the dust filter and the cooling pad 1 Remove the filter pad by unscrewing the screws on the...
Page 8: ...l board Motor does not respond to control panel Main control board failure Panel failure Change the main control board Change panel Water leaking from drain valve Drain valve is loose Dirt in valve Tighten drain valve nut Clean drain valve Air diffuser swing function not working Synchronous motor is burnt out Crankshaft is broken Change synchronous motor Change crankshaft Water drops splash out of...
Page 9: ...f the cooled air caused by the new cellulose panel We suggest you should complete at least one cooling cycle outdoors in an open space fill a water tank start the COOL function and let the appliance work until it finishes water completely before positioning and using it at the final place You can also add ice to water to maximise the appliance performance in the hottest weather as well as scented ...
Page 10: ... THE LONG RUN MIGHT DAMAGE THE PUMP MADE OF HIGH RESISTANCE AND HIGH QUALITY PLASTIC MATERIAL IT NEEDS THE INVOLVEMENT OF A PLUMBER TO INSTALL IT THE FILTER IS SUPPLIED WITH POLYPHOSPHATES CHARGE READY TO BE INSTALLED ONCE ITS EFFECTIVENESS HAS BEEN DEPLETED IT IS ENOUGH TO RECHARGE IT BY ADDING MORE POLYPHOSPHATES THAT CAN BE PURCHASED AT ANY HARDWARE STORE CHARACTERISTICS Working temperature 0 C...
Page 11: ...29 TELECOMANDO TELECOMMANDE REMOTE CONTROLLER PANNELLO DI CONTROLLO PANNEAU DE CONTROLE CONTROL PANEL SCHEMA ELETTRICO DIAGRAMME ÉLECTRIQUE DIAGRAM 11 ...
Page 12: ...MANUAL WATER FILLER REMPLISSAGE MANUEL DE L EAU PANNELLO LCD CONTROL PANNEL WITH LCD PANNEAU LCD COVER SUPERIORE TOP COVER CARROSSERIE RAFRAICHISSEUR RETE LATERALE LATERAL GRILLE DISTRIBUZIONE ACQUA WATER DISTRIBUTOR DISTRIBUTION EAU TUBO ACQUA WATER PIPE CONDUITE DEL EAU FILTRO ARIA FILTRE A AIR AIR INLET FILTER VENTOLA FAN HELICE MOTORE MOTOR MOTEUR SOSTEGNI MOTORE MOTOR BRACE SOUTIEN MOTEUR PAN...
Page 13: ...FFUSORE DIFFUSER DIFFUSEUR SERBATOIO ACQUA WATER TANK RESERVOIR D EAU INDICATORE LIVELLO ACQUA WATER GAUGE INDICE DU NIVEAU D EAU ROTELLE FRONTALI FRONT SWIVEL CASTER ROULETTE AVANT ROTELLE POSTERIORI CON FRENO BACK SWIVEL CASTER ROULETTE ARRIERE AVEC FREIN INGRESSO ACQUA RIEMPIMENTO MANUALE MANUAL WATER FILLER REMPLISSAGE MANUEL DE L EAU PANNELLO LCD CONTROL PANNEL WITH LCD PANNEAU LCD COVER SUPE...
Page 14: ...PIMENTO MANUALE MANUAL WATER FILLER REMPLISSAGE MANUEL DE L EAU PANNELLO LCD CONTROL PANNEL WITH LCD PANNEAU LCD COVER SUPERIORE TOP COVER CARROSSERIE RAFRAICHISSEUR COLLEGAMENTO CONTINUO ALLA RETE IDRICA EXTERNAL HOSE CONNECTION POINT CONNEXION AU ROBINET D EAU VALVOLA GALLEGGIANTE VALVE FLOTTANTE FLOAT VALVE DISTRIBUZIONE ACQUA WATER DISTRIBUTOR DISTRIBUTION EAU RETE POSTERIORE GRILLE GRILLE VEN...
Page 15: ...EL EAU DIFFUSER DIFFUSEUR WATER TANK RESERVOIR D EAU WATER GAUGE INDICE DU NIVEAU D EAU ROTELLE FRONTALI FRONT SWIVEL CASTER ROULETTE AVANT BACK SWIVEL CASTER ROULETTE ARRIERE AVEC FREIN RIEMPIMENTO MANUALE MANUAL WATER FILLER REMPLISSAGE MANUEL DE L EAU CONTROL PANNEL WITH LCD PANNEAU LCD COVER SUPERIORE TOP COVER CARROSSERIE RAFRAICHISSEUR MOTEUR OSCILLANT SWING MOTOR FAN HELICE COLLEGAMENTO CON...
Page 16: ...BULBO UV UV BULB LAMPE UV POMPA DELL ACQUA WATER PUMP POMPE DEL EAU SERBATOIO ACQUA WATER TANK RESERVOIR D EAU 16 ...
Page 17: ...est pas reconnue au cas ou l appareil ait été malmené ou quand il a été abîmé à cause de la négligence de l utilisateur maintient fait par personnel pas autorisé à cause du transport lorsque les instructions d utilisation n ont pas été respectées ou encore lorsqu il a été mal installé sans tenir compte des normes en vigueur La garantie ne prévoit absolument pas la substitution de l appareil Les ré...
Page 18: ...Ed 012020 IPX4 18 ...