SM SYGNUS SHC USER´S MANUAL
21
Cables
Straight CAT5 Gauge 24-shielded outdoor rated cable must be installed between Outdoor Unit and
Indoor Outlet. The cable should be UV resistant, flame retardant, UL listed and contain at least 4
twisted pairs.
The outdoor cables scheme is given in
Appendix A
–
Outdoor Cables Scheme.
The Indoor PoE Outlet side and Outdoor Unit side are crimped using RJ-45 tool.
__________________________________________________________________________________
CAT5 cable must not exceed 300 feet (91 meters).
__________________________________________________________________________________
The Outdoor Unit side will be assembled according to the following steps
• Insert seal bracket (grommet clamping plate) on the cable.
• Insert rubber seal (grommet) on the cable.
• Crimp the RJ-45 Plug.
Figure: Cable preparation for Outdoor Unit
• Insert the RJ-45 to the Outdoor Unit.
• Insert NC-6 screws with spring washer to the seal bracket.
Figure:
Cable assembly to Outdoor Unit