background image

Stanley TLM165I

1

EN

Table of Contents

Instrument Set-up

- - - - - - - - - - - - - - - - - - - - - - - 2

Introduction- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2
Overview  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2
Display - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3
Insert batteries  - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3

Operations

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4

Switching ON/OFF  - - - - - - - - - - - - - - - - - - - - - - - - - 4
Clear  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4
Message Codes  - - - - - - - - - - - - - - - - - - - - - - - - - - - 4
Adjusting measuring reference - - - - - - - - - - - - - - - - - 4
Distance unit setting  - - - - - - - - - - - - - - - - - - - - - - - - 5
Multifunctional endpiece- - - - - - - - - - - - - - - - - - - - - - 5

Measuring Functions

 - - - - - - - - - - - - - - - - - - - 6

Measuring single distance  - - - - - - - - - - - - - - - - - - - - 6
Permament measuring- - - - - - - - - - - - - - - - - - - - - - - 6
Add / Subtract - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6
Area- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7
Volume- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7
Pythagoras (2-point)  - - - - - - - - - - - - - - - - - - - - - - - - 8
Pythagoras (3-point)  - - - - - - - - - - - - - - - - - - - - - - - - 8
Memory (5 last results)  - - - - - - - - - - - - - - - - - - - - - - 9

Technical Data

 - - - - - - - - - - - - - - - - - - - - - - - - - 10

Message Codes

- - - - - - - - - - - - - - - - - - - - - - - - 11

Care

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11

Warranty

 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11

Safety Instructions

- - - - - - - - - - - - - - - - - - - - - 11

Areas of responsibility - - - - - - - - - - - - - - - - - - - - - - 11
Permitted use - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12

Prohibited use - - - - - - - - - - - - - - - - - - - - - - - - - - - -12
Hazards in use  - - - - - - - - - - - - - - - - - - - - - - - - - - -12
Limits of use  - - - - - - - - - - - - - - - - - - - - - - - - - - - - -12
Disposal - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -12
Electromagnetic Compatibility (EMC)- - - - - - - - - - - -12
FCC statement (applicable in U.S.) - - - - - - - - - - - - -13
Laser classification- - - - - - - - - - - - - - - - - - - - - - - - -13
Labelling - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -13

Summary of Contents for TLM165I

Page 1: ...ing Functions 6 Measuring single distance 6 Permament measuring 6 Add Subtract 6 Area 7 Volume 7 Pythagoras 2 point 8 Pythagoras 3 point 8 Memory 5 last results 9 Technical Data 10 Message Codes 11 Ca...

Page 2: ...tentially hazardous situation or an unintended use which if not avoided will result in death or serious injury CAUTION Indicates a potentially hazardous situation or an unintended use which if not avo...

Page 3: ...Battery Units Area Volume Min Max Measuring Measuring reference Info Addition Subtraction Pythagoras Memory Main line Insert batteries i To ensure a relia ble use do not use zinc carbon batteries Cha...

Page 4: ...action If the info icon appears with a number observe the instruc tions in section Message Codes Example Adjusting measuring reference Distance is measured from the front of the device 1 Distance is...

Page 5: ...Stanley TLM165I Operations 5 EN Distance unit setting 0 000m 0 00 1 16 0 in 1 16 Switch between the following units 2 sec Multifunctional endpiece...

Page 6: ...measuring time increases Permament measuring 1 2 sec 8 532 m Aim active laser at target 2 The last value mea sured is displayed Stops permanent measuring 3 Add Subtract 7 332 m 1 The next meas urement...

Page 7: ...sec ond target point 24 352 m2 5 i The result is shown in the main line and the measured value above Volume 1 2x 2 Aim laser at first target point 3 4 Aim laser at sec ond target point 5 6 Aim laser...

Page 8: ...ressing the meas uring key for 2 sec in the function acti vates automatically Minimum or Maxi mum measure ment Pythagoras 3 point 1 4x 2 Aim laser at up per point 3 4 Aim laser at rec tangular point 5...

Page 9: ...Stanley TLM165I Measuring Functions 9 EN Memory 5 last results 8 294 m 5 5 last results are displayed 1 5x 8 294 m 5 Navigates trough 5 last results 2...

Page 10: ...ce 3 0 mm 0 12 in Range at Target Plate 60 m 197 ft Typical Range 50 m 164 ft Range at unfavourable condi tion 40 m 132 ft Smallest unit displayed 1 mm 1 16 in laser point at distances 6 30 mm 10 50 m...

Page 11: ...www STANLEYLASERS com www STANLEYTOOLS com www STANLEYTOOLS eu The company above is responsible for supplying the product including the User Manual in a completely safe condition The company above is...

Page 12: ...been subject to abnormal use and before during and after important measurements CAUTION Never attempt to repair the product your self In case of damage contact a local dealer WARNING Changes or modif...

Page 13: ...he receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dea...

Reviews: