Thank you for purchasing a STANLEY forced air heater. Please keep your User’s Manual for future reference 

and seasonal servicing recommendations.
Locate the LP cylinder at least 1.8 metres (6 feet) from the heater, and do not direct the heater discharge to-

wards the LP cylinder unless it is at least 6 metres (20 feet) from the heater. Use only the regulator and hose 

assembly provided with this heater. You may use a 9 - 45 kg LP cylinder.

How to Get Your New Heater Quickly Up and Running

1. Familiarize yourself with all safety instructions in the front of your User’s Manual.
2. Remove the heater from the box. Ensure all parts are included and assemble per the instructions.
3. Remove any protective material applied to the heater for shipment.
4. Check the heater for damage. If damage is found, contact the service partner.
5. Ensure the heater Valve Knob and the Supply Valve on the tank are turned to the OFF position.
6. Fasten the propane cylinder to the heater’s regulator and the hose to the inlet connector on the heater.
7. Plug in the heater to a minimum 1.8 m (6-foot), 0.75 mm

2

, 3-prong grounded extension cord.

8. Open the supply valve of the propane tank. Press down and turn the heater control knob to the “1” 

position (ignition). Keep the valve knob depressed for at least 30 seconds. If the burner does not stay lit,

repeat the lighting procedure. Only use this heater in a well-ventilated outdoor space!

• NOTE:

  If you have a ST-40-GFA-E with piezo electric spark ignition, you may need to keep switching from

the “O” (off) to the “1” position multiple times for ignition.

This heater is manufactured for use with propane gas only. DO NOT attempt to convert it to any other 

gas. Such modifications are dangerous and will void the warranty.

For continued difficulties or items not covered here, see the Troubleshooting Guide in the User’s Manual.

STG

B

-4

46

This is an unvented portable heater. It uses air (oxygen) from the area in which it is used. Adequate combus-

tion and ventilation air must be provided. Please read the User’s Manual very carefully and understand all 

warning statements. The manual has been designed to instruct you on the proper operation, maintenance, 

and storage of your new heater.

PROPANE FORCED AIR HEATER 

QUICK-START GUIDE

Propane Forced Air Heater Quick-Start Guide 

Obelis S.A

Registered Address:

Bd. Général Wahis, 53

1030 Brussels, Belgium

© 201

8

 Stanley Black & Decker, Inc.

Pinnacle Climate Technologies, Inc.

Sauk Rapids, MN 56379 USA

EC REP