Installation Instructions
LED Outdoor Flood Light
IMPORTANT: READ ALL INSTRUCTIONS BEFORE THE INSTALLATION.
CAUTION:
This product use an input 120v vac driver, the actual working voltage is dependent on the input voltage
of the photocell that is installed on the product (photocell is optional). An internal power-factor-corrected switch-
mode supply allows it to be used from any nominal 120 v, 50/60 hz ac supply without any variation in light output.
NOTE: SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
WARNING:
Risk of fire or electric shock. The installation should be performed only by a qualified electrician in
accordance with the National Electrical Code and relevant local codes. This product must be installed in full
accordance with applicable electrical and building codes. This fixture is for outdoor use and should not be used
in areas with limited ventilation or high ambient temperatures.
WARNING - TO AVOID ELECTRIC SHOCK:
• Be certain electrical power is OFF before and during installation and maintenance.
• Luminaire must be connected to a wiring system with an equipment-grounding conductor.
WARNING - TO AVOID EXPLOSION:
• Make sure the supply voltage is the same as the rated luminaire voltage.
• Do not install where marked operating temperatures exceed the ignition temperature of
the hazardous atmosphere.
• Do not operate in ambient temperatures above those indicated on the luminaire.
• Keep lens tightly closed when in operation.
• For supply connections use wire rated for at least 90°C.
KNUCKLE MOUNT: INSTALLATION INSTRUCTIONS
1. Use a screwdriver to loosen the screw on the mounting Knuckle (FIG. 1).
2. Adjust the mounting knuckle to the desired angle (FIG.2) Tighten the screw (FIG 3)
3. Keep enough wire length to ensure adjusting angle unhindered.
4. Connect wires into wiring terminal; white wire to “Neutral” terminal, black wire to “Live” terminal, green wire to
“Ground” terminal; and fix them by screws: Secure service wire or conduit to the wiring compartment cover
with ½” connector (not provided). Connect white fixture wire to white supply wire, black fixture wire to black
supply wire. Service ground should be attached to green ground wire. Ground must be properly attached to
avoid the risk of electrical shock. Use wire nuts to connect all wires. Make sure connections are secure and that
no loose wire strands are sticking out of connectors.
5. The floodlight can be mounted directly to a pole with ½” threaded insert. (FIG. 4)
6. Turn on power and installation is complete.