Page 27
GX2200
6.11 OPTIONAL CMP30
(
RAM3
)
INSTALLATION
The
GX2200
is capable of using a
CMP30
(
RAM3
) Remote Station Micro-
phone to remotely control the Radio, AIS, DSC and PA/Fog functions. In
addition the
GX2200
can operate as a full function intercom system between
the
CMP30
(
RAM3
)
and the
GX2200
.
WARNING
Do not connect or remove the CMP30 (RAM3) microphone while
the radio is powered on. This may result in equipment failure.
1. Connect the extension cable to
the remote microphone eight
pin connector on the rear panel,
then tighten the cable nut (see
illustration at the right).
2. Install the ferrite core (supplied with the
CMP30
(
RAM3
)
Remote Station
Microphone) to the extension cable, then snap its two halves together,
per the illustration on the next page.
3. Attach the ferrite core as close as possible to the MIC plug, as shown
below.
4. Finally, wind some plastic tape
around each ferrite core, to
prevent vibration from causing
the two halves to split apart.
As close as possible
Routing Cable or
CT-100 Extension Cable
Ferrite Core
Snap together
External Speaker
Connections
5. Referring to illustration below, make a 1.2” (30 mm) hole in the wall, then
insert the extension cable into this hole. Connect the gasket and mount
base to the extension cable connector using the nut.
6. Drill the four screw holes (approx. 2 mm) on the wall, then install the
mounting base to the wall using four screws.
7. Put the rubber cap on to the nut. The installation is now complete.