Page 28 of 56
1.20.1
Bill Acceptor Stacker Full Alert
The settings allow you to display the number of bills accepted for each stacker. The settings are for
each individual acceptor in the machine. This can be useful if you want an advanced notice before a
bill acceptor stacker goes full.
x
Stacker Full Alert –
Enter the number of bills to be accepted before an alert will be sent. A
non-zero entry will cause the count to be displayed on the internal display.
x
Stacker Full Count –
The number of bills accepted since the last clear. Pressing YES or
CLEAR will clear this count. This should be done every time you empty the stacker.
1.20.2
Dispenser Sold Out Alert
These settings allow you to display a countdown of the number of items left and/or send an email
alert if the number of items left is less than the alert level. The settings are for each individual
dispenser in the machine. This can be useful if you want an advanced notice before a dispenser goes
sold out. These settings are stored in the dispenser, not in the EF+. If you change out a dispenser,
please check these settings.
x
Dispenser Fill Level
– Enter the fill level. This is the number of items that the dispenser holds
after you fill it. If the total number of quarters in the dispenser is 2000, Dispenser Fill Level =
2000. If this is not zero, the dispenser count will be displayed on the internal display.
x
Dispenser Alert Level
– Enter the alert level. This is the number of items still in the dispenser at
which you want an email sent warning you that the dispenser will soon go sold out. Dispenser
Alert Level = 500.
x
Reset Dispenser Count
– This is a YES/NO question. YES, will reset the count back to the
original fill level when you exit. This should be done every time you top the dispenser off to the
fill level.
1.20.3
Display Dispense Amounts
Entering YES will display the live dispenser counts and bill acceptor stacker counts on the external
EF+ display when the key switch is used.
As an example: you fill your 25¢ coin dispenser A with 2000 ($500) coins. That is the total number
of coins in the dispenser. The
Dispenser Fill Level
should be 2000. You set the
Dispenser Alert Level
to 500. After the dispenser has dispensed 1500 coins the machine will email a dispenser alert (if you
have setup emailing a dispenser alert in EMAIL SETTINGS). This can be done because the dispenser
is counting the coins that are being dispensed and it knows when it reaches the alert level. The more
accurate your
Dispenser Fill Level
is the more accurate the dispenser alert will be. When you top off
the dispenser to 2000 coins you would
Clear Dispenser Count
(YES) to the
Dispenser Fill Level
(2000).
1.21
MiniMech Bill Dispenser Settings
The Glory MiniMech bill dispenser does not have a sold out circuit.
The DISPENSER ALERT SETTINGS are very important in calculating when the bill dispenser will
be sold out. Only the Fill Level and resetting the Dispenser Count in DISPENSER ALERT