Stancor WCP Series Installation, Operation And Maintenance Manual Download Page 1

 

 

 

________________________________________________________________________________ 

_________________________________________________________________________________  

 

EI-700-011 Rev 1 

 

 

 

Installation, 

Operation 

And Maintenance 

Manual 

 

 

 

 

 

 

 

 

 

Stancor

™ 

WCP Series 

Pumps

 

 

 

Summary of Contents for WCP Series

Page 1: ..._______________________________________________________ _________________________________________________________________________________ EI 700 011 Rev 1 Installation Operation And Maintenance Manual...

Page 2: ...llowing points upon receipting of your pump 7 Installation 7 Electrical Wiring 8 Wiring 8 Cable 8 Grounding 8 Wiring Diagrams 8 Operation 9 Maintenance 9 Exploded View 10 Troubleshooting 11 Disassembl...

Page 3: ...ed risk of electric shock during operation of this pump requires the provision of acceptable grounding When the means of connection to the supply connection box is other than grounded metal conduit gr...

Page 4: ...s when handling solids install in a horizontal position or at an angle of no more than 45 Do not install check valve in avertical position as solids may settle in valve and prevent opening on start up...

Page 5: ...ices without consulting with a STANCOR representative The product is designed for moving wastewater raw and clean water The following shall not be handled for the pump and your safety i Flammable toxi...

Page 6: ...rmat Name Description Serial No Serial Number Model Pump Model Frequency Power Frequency Hz Head Maximum Pressure Head m Output Pump Output BHP Hp Voltage Operating Voltage V Revolution Rotational Spe...

Page 7: ...ed on a hard level surface Never place pump directly on clay earth or gravel surfaces Pump can be installed with ABS PVC polyethylene or galvanized steel pipe Proper adapters are required to connect p...

Page 8: ...opriate start system as shown inFig 3 for single phase version andFig 4 for three phases B Loose connections will stop the pump Make sure all electrical connections secure Cable WARNING Never let the...

Page 9: ...gh within the limits of pump rating foreign matter may be clogged the pump If the volume of liquid discharged falls suddenly foreign matter may be blocked the suction inlet 2 Regular inspections Month...

Page 10: ...View Pos No Denomination Pos No Denomination 1 Discharge 8 Shaft sleeve 2 Upper cover 9 Impeller 3 Outer case 10 Pump casing 4 Motor 11 Inlet plate 5 Mech seal 12 Strainer 6 Seal bracket 13 Base plate...

Page 11: ...t pump Inadequate volume 1 Reverse rotation 1 Correct rotation see Operation 2 Significant drop in voltage 2 Contact electric power company 3 Operating a 60Hz pump with 50Hz 3 Check nameplate 4 Discha...

Page 12: ...ove oil filler plug and drain lubricating oil 4 Remove intermediate casing bolts and oil chamber Remember that any lubricating oil remaining in the mechanical seal chamber will flow out 5 Carefully re...

Page 13: ...WCP 1100 HH DS A28 006 Pump Curves WCP WCP 400 HH DS A28 003 WCP 400 HV DS A28 011 WCP 1100 HH DS A28 007 Outline Drawings WCP WCP 400 HH DS A28 004 WCP 400 HV DS A28 012 WCP 1100 HH DS A28 008 List o...

Page 14: ...Industrial Flow Solutions Operating LLC 104 John W Murphy Drive New Haven CT 06513 USA 860 399 5937 www flowsolutions com Stancor is a trademark of Industrial Flow Solutions Operating LLC All rights...

Page 15: ...15...

Reviews: