7.1 Manual control
In manual operation, the device functions are controlled by the function buttons of the control
panel and the display.
Press
[FUNCTION]
to open the main menu. The display shows
‘Wait Time Set Mode: xx s’
. Use
the two arrow buttons to set the waiting time for the timer function in a range of 1 … 600 .
Press again
[FUNCTION]
. The display shows
‘Start Time Set Mode: xx s’
. Use the two arrow but-
tons to set the time period during which the device will continuously produce haze after the
waiting time of the timer function or after pressing the button
[VOLUME]
(1 … 600 seconds).
Press again
[FUNCTION]
. The display shows
‘Timer Smoke Volume Out: xx %’
. Use the two arrow
buttons to set the haze output volume in a range 1 … 100 %.
Press again
[FUNCTION]
. The display shows
‘Fan Adjusting Volume: xxx %’
. Use the two arrow
buttons to set the haze output intensity in a range 1 … 100 %.
7.2 Operating mode ‘DMX’
Press
[FUNCTION]
repeatedly until the display shows
‘The DMX device address set: 1’
. Use both
arrow buttons to select a DMX address in a range from 1 … 510.
Operating
HF-900 Haze Fogger
29