Pendant Light Fitting LED
Series 6470/5
After the test:
Ceiling and pendant light fittings and lights with mounting brackets
• Remove the hose of the test device for testing restricted breathing from the cable
entry.
• Remove the M20 cable entry.
• Insert the stopping plug.
For wall mounting and pole mounting
• Remove the hose of the test device for testing restricted breathing from the cable
entry.
• Remove the M20 cable entry.
• Remove the test adapter.
• Reinsert the screw with seal.
Alternative pressure and time specifications:
9.2
Repair
9.3
Returning the device
• Only return or package the devices after consulting R. STAHL!
Contact the responsible representative from R. STAHL.
R. STAHL's customer service is available to handle returns if repair or service is required.
• Contact customer service personally.
or
• Go to the r-stahl.com website.
• Under "Support" > "RMA form", select "Request RMA slip".
• Fill out the form and send it.
Confirmation will be sent. R. STAHL's customer service will contact you.
You will receive an RMA slip after speaking with customer service.
• Send the device along with the RMA slip in the packaging to
R. STAHL Schaltgeräte GmbH (refer to chapter 1.1 for the address).
Alternative 1
Alternative 2
Vacuum at start of test
3.0 kPa (30 mbar)
0.3 kPa (3 mbar)
Test duration
14 seconds
14 seconds
Vacuum after testing
2.7 kPa (27 mbar)
0.27 kPa (2.7 mbar)
DANGER
Explosion hazard due to improper repair!
Non-compliance results in severe or fatal injuries.
• Repair work on the devices must be performed only by
R. STAHL Schaltgeräte GmbH.