Pendant Light Fitting LED
Series 6470/5
Preparing the luminaires for testing:
Ceiling and pendant light fittings and lights with mounting brackets
For wall mounting and pole mounting
Test:
• Insert the hose of the test device into the cable entry for testing restricted breathing.
• Hand-tighten the cable entry.
• Use the hand pump to create a vacuum of 0.3 kPa (3 mbar).
The test has been passed if after 90 seconds a vacuum of at least 0.15 kPa (1.5 mbar)
is still present in the luminaire.
19699E00
• Remove the stopping plug.
• Insert the M20 cable entry.
19701E00
• Remove the screw and seal.
19700E00
17143E00
• Screw the test adapter into the
thread.
• Insert a M20 cable entry into the
test adapter.