© 2022 Staheli West
205
Tests
Test 6: Intermittent Pilot Flame Test
1. Start the burner.
2. When the burner goes into pilot ignition, move the switch to the “Test” position (this
will hold the burner in pilot mode until the switch is placed in the “Run” position).
3. Remove top cap on the propane regulator with a flat head screwdriver.
4. While observing the pilot flame through the sight glass, adjust the regulator to stabilize the flame.
*Propane Pressure at pilot:
4-7 WC (Water Column)
0.14 - 0.25 psi
1
1
2
2
3
3
4
4
Test 7: Leaky Igniter Test
1. Remove the igniter assembly and disconnect the propane hose.
2. Spray soapy water on and in the igniter housing.
3. Blow a very small amount of compressed air in the propane inlet of the igniter housing.
4. Bubbles will form if there is a leak.
If your housing is compromised, you will need to order a new burner igniter assembly.