Faults
Fault 205: Pilot Propane Pressure Low
Indicates that there is no/low pressure in the propane line (Sensor is located at the front left side of the
steamer).
Fault can be disabled in Menu>Settings>Pilot
Propane>Pilot Propane Alarm Disable.
Causes
Troubleshooting
Fixes
• Propane tank valve closed.
• Check valve position.
• Open propane tank valve.
• Propane tank empty.
• Check propane level.
• Refill propane tank.
• Faulty/dirty propane psi sensor.
• Remove and inspect sensor.
• Clean/Replace propane psi
sensor.
• Clogged propane tank regulator. • Inspect regulator.
• Clean/Replace propane tank
regulator.
• Faulty wiring.
• Inspect the wiring for ground,
continuity, and proper voltage.
• Replace/Repair wiring.
Fault 206: Supply Water Is Empty
Indicates that the supply water is empty.
Causes
Troubleshooting
Fixes
• Supply water is empty.
• Fill the supply water tanks with treated water.
• Sensor is disconnected.
• Check to see if sensor is
disconnected.
• Connect sensor.
• Sensor valve is closed.
• Check to see if valve near
sensor is closed.
• Open valve.
• Faulty sensor.
• Replace sensor.
• Damaged wire harness.
• Inspect 70-pin wire harness for
water damage.
• Repair/Replace damaged
components.
• Faulty wiring.
• Inspect the wiring for ground,
continuity, and proper voltage.
• Replace/Repair wiring.