003-2598 Rev A
User Manual
Standby UPS
350VA/550VA/750VA
Inspection
The following items are inside the box:
●
UPS unit
●
User manual
Remove the UPS from its package and inspect it for damage that
may have occurred during shipping. If any damage is discovered,
re-pack the unit and return it to the place of purchase.
Connect to Utility Power
Connect AC power cord to utility power. Then, the UPS will start to
charge inside battery. For best result, charge the battery for 6 hours
prior to initial use.
Plug in Equipment
Battery Backup Outlets
Connect computer and monitor to the "Battery Backup" outlets.
These outlets provide battery backup, EMI filtering, line
conditioning, and surge protection. Battery power is automatically
provided in case of power failure.
Surge-Protected Outlets
Connect a printer, fax
machine, or scanner to the “Surge-protected”
outlets. These outlets do not provide power during power failure.
CAUTION: NEVER
connect a laser printer or scanner to the
battery backup sockets of UPS. The equipment may draw
significantly power to overload the UPS.
AVERTISSEMENT:
Ne jamais raccorder une imprimante laser ou
un scanner pour les prises de sauvegarde batterie de l’onduleur.
L’équipement peut exiger beaucoup d’énergie de surcharger le
système UPS.
Turn On/Off the UPS
To turn on the UPS unit, press the power switch lightly. Then, the
LED or LCD will light up. To turn off the UPS unit, press the power
switch again. Then, display will shut off.
LED
Alarm
UPS Status
●
Green
Off
The mains is normal and
UPS is operated normally.
★
Yellow
Sounding every
10 seconds
Power failure occurs and
UPS is on battery mode.
★
Yellow
Sounding every
second
Low battery
○
Green
Off
UPS is off.
●
Red
Continuously
sounding
UPS fault
●
LED on
○
LED Off
★
LED flashing
Operation Display
UPS
Mode
LCD
Description
UPS
Power on
When UPS is powered
on.
AC Mode
LCD information will be
displayed in the
following order when
LCD is touched.
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity
Overload
in AC
mode
icon will flash.
When overload occurs,
alarm will beep every
0.5 second.
Battery
Mode
When battery level is low,
icon will flash.
Alarm will beep every
10 seconds and LCD
information will be
displayed in the
following order when
LCD is touched.
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity
Overload
in battery
mode
icon will flash.
When overload occurs,
alarm will beep every
0.5 second.
NOTE:
If backlight shuts off, you may activate it by touching the
screen.
Remarque:
Si le rétro-
éclairage s’éteint, vous pouvez l’activer en
touchant l’écran.
Fault Code Table:
Fault condition
LCD
Solutions
Output short
circuited
Disconnect short-circuited
loads and restart the UPS
again.
Overload fault
Disconnect output loads and
restart the UPS again.
Overcharge
Call for service immediately.
Bad or severely
discharged
battery
Please replace the battery.
High output
voltage fault
Call for service immediately.
If fault alarm occurs, please call for service immediately.
INSTALLATION & OPERATION
PRODUCT OVERVIEW
LCD DISPLAY
LCD display or LED indicators
(Please check LED or LCD section
for the details)
Power switch
AC input
Battery backup outlets
Surge-protected outlets
USB port (option)
LED Indicators
WARNING:
Changes or modifications not expressly approved
by the party responsible for compliance could void the user's
authority to operate the equipment.
AVERTISSEMENT
: Changements ou modifications non
expressément approuvées par la partie responsable de la
conformité pourraient annuler l’autorisation de l’user\ pour faire
fonctionner l’équipement
.