12
en
9.2 Manual operation without tilt function
In manual operation without tilt function, automatic mode,
the tilt function and relevelling are not active. The laser unit
is aligned entirely by hand. The unit does not level itself.
Place the laser unit in the working position. Press button (3)
twice = once to switch on + once to deactivate tilt function.
Press button (4) once
= change over to/activate manual mode.
The white LED (5) flashes. The blue (8) and green (9) LEDs
light up steadily. The laser beam rotates. The laser plane can
be set up by direction-finding or by taking measurements.
Summary of Contents for LAR 300
Page 1: ...Operating instructions...