background image

LA 90L / LA 180L

Operating instructions

en

Summary of Contents for LA 180L

Page 1: ...LA 90L LA 180L Operating instructions en ...

Page 2: ...A 3a 3b 4 5 6 7 8 LA 180L ...

Page 3: ...1d 1c 1a 1b 2b 2a B LA 180 L LA 90 L C A1 ...

Page 4: ...E1 E2 D1 90 2 8m D2 1 1 2 E3 1 2 D D X Y F 5 11 ft 3 1 3 ft Y Y 1m ...

Page 5: ...1 A G4 2 B 1 A 2 B 1 A 2 B 2 3 S 5 m 16 ft 3 1 3 G1 D3 2 8m G5 G3 G2 11 ft ...

Page 6: ...y time Telephone number 0049 63 46 3 09 0 Main components 1a 1b 1c 1d 2 2a 2b 3a 5 6 7 8 9 On off button Button automatic levelling on off manual mode Button horizontal line on off Button vertical lines on off LEDs for displaying LED green Operating mode ON or READY OK LED red battery voltage and overheat Exit aperture for the horizontal and vertical laser lines Adjusting screw precision adjustmen...

Page 7: ...yes are normally protected from accidental short term exposure to the laser beam by the lid closing reflex and or the reflex reaction to turn one s head If a laser beam should encounter your eye you should consciously close your eyes and immediately move your head out of the beam Do not look directly into the direct or reflected beam The laser goggles enclosed with these units are not safety goggl...

Page 8: ...uch is outside the self levelling range the laser cannot level itself automatically Button 1d different vertical laser lines can be switched on off in succession The plumb line point is also switched on off at the same time All the vertical laser lines can only be switched off if the horizontal laser line is switched on If button 1d is pressed again the vertical laser lines are switched on again i...

Page 9: ...n 1d 4 Place the laser so that its down beam is aligned over a reference mark on the floor 5 Mark the position of the laser cross on the ceiling 6 Rotate the laser through 180 and realign the laser beam on the reference mark on the floor 7 Mark the position of the laser cross on the ceiling 8 Measure the differences in the x and y directions between the two marks on the ceiling The difference is t...

Page 10: ...A B C D E A E I2 L 10m H3 H2 A B C D L 10m H1 A B C I3 I1 16 5 32 10 16 5 16 5 16 5 16 5 16 5 32 10 ...

Page 11: ...the angular accuracy of the vertical lines checking the 90 angle of the vertical lines Note In order to guarantee accuracy the distance of A to B B to C and B to D should be equal 7 Rotate the LA 90L LA 180L through 90 so that laser line 1 is aligned with point D 8 Mark position E of the right angle laser line 2 as close as possible to point A on the floor 9 Measure the distance between points A a...

Page 12: ...first wall step 3 point 1 2 Horizontal checking inclination of the laser line Check the laser line for inclination and perfectly straight projection 1 Mark three points 1 2 and 3 on the floor at a distance of 5 m 16 5 from each other the points must be in a perfectly straight line 2 Position the laser at distance S 5 m 16 5 from the line and exactly in front of the middle point you marked position...

Page 13: ...g period Only LA 180L Registering the REC 410 Line RF receiver with the laser transmitter 1 Switch off the laser transmitter button 1a 2 Press and hold down buttons 1c and 1d 3 Switch the unit on button 1a 4 The laser transmitter is in registration mode The LEDs red and green flash alternately 5 Press the button automatic precision alignment d on the REC 410 Line RF receiver 6 The red and green LE...

Page 14: ...ed imminently Illuminated red LED laser beam flashing The laser levels itself automatically Battery voltage very low Battery replacement required imminently Flashing red LED laser beam flashing Battery voltage very low The unit is inclined too much is outside the self levelling range the laser cannot level itself automatically The temperature in the unit is over 50 C 122 F The laser diodes have be...

Page 15: ...ty Also no claims under guarantee are accepted for natural wear and tear or any small faults that do not significantly affect the unit s operation Any guarantee claims must be made via the dealer on the duly completed guarantee form see last page to be returned with the unit Technical data Laser type line Laser type plumb line point Output Self levelling range Levelling accuracy Middle of the lase...

Reviews: