STM32F103xx
Electrical characteristics
27/67
5.3 Operating
conditions
5.3.1
General operating conditions
5.3.2 Operating
conditions
at power-up / power-down
The parameters given in
are derived from tests performed under the ambient
temperature condition summarized in
.
Table 8.
Operating conditions at power-up / power-down
Table 6.
Thermal characteristics
Symbol
Ratings
Value
Unit
T
STG
Storage temperature range
–65 to +150
°C
T
J
Maximum junction temperature (see Thermal characteristics)
Table 7.
General operating conditions
Symbol
Parameter
Conditions
Min
Max
Unit
f
HCLK
Internal AHB clock frequency
0
72
MHz
f
PCLK1
Internal APB1 clock frequency
0
36
f
PCLK2
Internal APB2 clock frequency
0
72
V
DD
Standard operating voltage
2
3.6
V
V
BAT
Backup operating voltage
1.8
3.6
V
T
A
Ambient temperature range
−
40
105
°C
Symbol
Parameter
Conditions
Min
Typ
Max
Unit
t
VDD
V
DD
rise/fall time rate
20
µs/V
20
ms/V