DocID026814 Rev 1
9/52
UM1811
Getting started
52
Figure 4. Node connection
Once the Open button has been selected (1), the trace window (2) allows checking that the
command has been correctly transmitted to the evaluation board. The G3-PLC GUI
command panel has as much tab as G3-PLC platforms are connected. To identify the tab,
the associated COM port is displayed in the panel title (3).
3.2
Node tree panel
The G3-PLC GUI offers access to the “Service Access Points” (SAP) of each layer specified
by the G3-PLC standard plus some additional features such as a bootstrap application or
the G3 library configuration.
Once a G3-PLC platform is connected, it can be explored thanks to the object tree panel.
Each root menu can be collapsed or not to see its detailed content. The detailed content
gives access to each specific SAP: PHY, MAC, ADP, BOOT and G3LIB.
Additional levels of the interface (such as IPv6) may be present. The related functions may
be used in conjunction with specific firmware projects that may be obtained from your local
support.