St George RHSGSPOT Operation Manual Download Page 1

Rangehood

Appliance Operation Manual

INCLUDING INSTALLATION AND CLEANING

RHSGSPOT - 1200mm Wall Mounted Canopy

Summary of Contents for RHSGSPOT

Page 1: ...Rangehood Appliance Operation Manual INCLUDING INSTALLATION AND CLEANING RHSGSPOT 1200mm Wall Mounted Canopy ...

Page 2: ...itage of innovation and quality Our success extends to domestic and overseas markets confirming our reputation at the forefront of appliance excellence The elegant simplicity and high performance features of St George designs will remain contemporary in many years to come ...

Page 3: ...6 7 1 4 4 2 3 5 6 5 2 3 1 4 7 6 7 2 3 1 4 6 7 2 3 1 3 6 7 2 1 4 1A 1B 1C 1D 1E ...

Page 4: ...6 7 1 4 5 4 3 2 6 7 4 4 2 3 5 6 7 1 4 4 3 2 5 6 7 1 3 2 5 8 6 2 1 4 7 5 3 6 7 4 5 1 2 3 1G 1F 1H 1I 1J 1K ...

Page 5: ...g g j h i g g q r s t u f f a 2 3 4A 4B 4C 5D ...

Page 6: ...6A 6B 20b 20b 7 16 7 16 4 5 6 12 13 8 9 14 14 15 18 20a 20a 9 8 19 8 9 B G H 11 11 10 17 F ...

Page 7: ...6C 20b 20b 7 16 7 16 4 5 6 12 13 8 9 14 14 15 18 20a 20a 9 8 19 8 9 3 3 3 2 B G H 11 11 10 17 F 1 1 1 1 1 ...

Page 8: ...6D 6I 20b 20b 7 16 7 16 4 5 6 12 13 8 9 14 14 15 18 20a 20a 98 19 8 9 1 17 B G H 11 11 10 1 1 1 3 3 21 F 1 2 2 3 3 ...

Page 9: ...6E 20b 20b 7 16 4 5 6 13 9 8 14 15 18 20a 20a 8 9 19 8 9 B G H 11 11 10 17 1 12 1 21 F 2 2 2 3 ...

Page 10: ...6F 6G 6H 7 16 7 16 5 6 12 13 8 9 18 20a 20a 98 19 8 9 1 17 B H 11 11 10 1 21 2 2 3 14 20b F 15 G 20b 4 1 1 1 3 22 1H 6H 1H 6H 22 ...

Page 11: ...19 17b 7 16 5 6 13 14 15 18 20a B G 11 10 17 12 17b 11 H 20a 8 9 4 22a 22b F 21 6J ...

Page 12: ...20b 20b 7 16 7 16 4 5 6 12 13 8 9 14 14 15 18 20a 20a 9 8 19 B G H 11 11 10 17 F 21 8 9 12 13 10 17 17 6K ...

Page 13: ...ersion then it is possible to overturn the upper section of the chimney and insert it inside the lower section of the chimney so that the air exit perforations are not visible The chimneys in which this operation is possible are recognisable by their bracket fixing points G which are repeated also in the lower side of the upper section of the chimney see installation sequence 20a 20b Attention For...

Page 14: ...placed inside the rangehood Connect the electrical plug where provided to the an easily accessible outlet in conformity with local standards in force Where an electrical plug is not provided for direct connection to electrical network place a standards approved bipolar switch with an aperture distance of not less than 3mm accessible from the contacts Description of the Rangehood Fig 1 1 Control pa...

Page 15: ...lling out the plug Then plug it in again and try once more before contacting the Technical Assistance Service Warning Always press the fan off button A before disconnecting the rangehood from the mains supply A B C D E F Operation Model with electronic controls 1 Motor OFF button 2 ON button and motor speed selection button 1 2 3 1 2 3 Speed 1 LED 4 Speed 2 LED and metal grease filter saturation L...

Page 16: ...ract the guard by levering it off with a small screwdriver or similar tool fig 4B 2 Replace the damaged light bulb Only use halogen bulbs of 20W max G4 making sure you do not touch them with your hands 3 Close the lamp cover it will snap shut For models shown in Fig 1J 1 Use a small screwdriver as a lever on the borders of the lamp in order to remove the lightbulb 2 Unthread the connector A 3 Slid...

Page 17: ... pay for the cost of transporting the appliance to and from the Agent or the Agent s travelling cost to and from the Purchaser s home WHAT THESE WARRANTIES DO NOT COVER We are not responsiblefor any damageor malfunctionunlesscausedby a defectin materialor workmanship This includes but is not limited to abuse misuse improper installation and transportation damage We are not responsible for any cons...

Page 18: ...A Tradition of Excellence 1300 305 366 ...

Reviews: